Wolf FWS-2-60L Manual page 21

Freshwater module, circulation module
Hide thumbs Also See for FWS-2-60L:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14
Setting the DHW circulation
shut-off temperature
3064342_201505
Installing the BSP-ZP DHW circulation
module
Set the temperature select screw (A) to the required temperature.
DHW circulation is disabled when the shut-off temperature is reached.
The temperature set on the DHW circulation unit (A) must be at
Note
least 10 K below the DHW temperature of the freshwater module
to prevent DHW circulation from operating continuously.
Observe all national codes for drinking water hygiene.