9. REMOVAL AND REPLACEMENT OF MEDIA
9. REMOVAL AND REPLACEMENT OF MEDIA
4. Loosen the P-2.6x6 screw and move the label guide plate according to the media width.
5. Secure the label guide plate with the P-2.6x6 screw.
Screw (P-2.6x6)
48-mm label dowel
57-mm label dowel
Label Guide Plate
NOTE: Ensure that the label guide plate aligns with the dowel.
6. Refer to the figure below and set the media on the label cassette.
7. Insert the roll stopper into the media core fully.
8. Set the backing paper stopper in the proper orientation.
Roll Stopper
Roll Stopper
Label or Report Paper
Label
Backing Paper Stopper
9. Assemble the label cassette to the scale and remove slack of the media.
Push down the print head, and close the right cover.
NOTE: After replacing the media, press the feed key to confirm that the media is issued correctly.
*Use of other model's label cassette in the SL-9000 may cause a label skew.