Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.
Wrap the refrigerant pipes and the drain
hose up in the absorbent pad and the
vinyl tape; refer to page 19.
4inch
(100mm)
minimum
24inch
(600mm)
minimum
❊ The designs of the unit and the connection valve are subject to change according to the model.
➢ The indoor unit must be installed at a height of 8.2ft(2.5m) at least from the floor of the room.
5inch
(125mm)
or more
24inch
49.3ft(15m) maximum
(600mm)
minimum
4inch(100mm)
minimum
14inch(350mm)
minimum
1inch(30mm) or more
5inch (125mm)
or more
23ft(7m) maximum