Siemens SIMODRIVE 611 universal Function Manual page 56

Control components for closed-loop speed control and positioning
Table of Contents

Advertisement

1 Product Overview
1.4
"SIMODRIVE 611 universal E" control board
Table 1-8
Differences with respect to "SIMODRIVE 611 universal", continued
Differ-
Differ-
SIMODRIVE
ence
ence
611 universal
S
Software
SW 1.1
S
release
SW 2.1
S
SW 2.4
S
SW 3.x
S
SW 4.1
S
SW 5.1
S
SW 6.1
Module
The module is identified using
type
P0870 (module type)
S
Analog
T. 56.x/14.x
S
inputs
T. 24.x/20.x
S
Digital in-
Term. I0.x
S
puts:
Term. I1.x
S
Term. I2.x
S
Term. I3.x
S
Digital
Term. O0.x
S
outputs:
Term. O1.x
S
Term. O2.x
S
Term. O3.x
Optional
Yes,
TERMI-
can be used
NAL
module
S
Optional
PROFIBUS
TERMI-
DP1
S
NAL
PROFI-
module
BUS–DP2
S
PROFI-
BUS–DP3
S
Serial in-
RS232
S
terface
RS485
(indepen-
dent of the
hardware)
1-56
611 universal E
S
no
Software release 3.1 is the first software release which
S
is used for both modules.
no
S
The following applies for "SIMODRIVE 611 universal E":
no
S
Software from SW 3.1 onwards must be used.
SW 3.x
S
SW 4.1
S
SW 5.1
S
SW 6.1
P0870 = 0004
––> it involves a "SIMODRIVE 611 universal E" control
board, 2–axes for encoders with sin/cos 1 Vpp
S
no
The information in Chapter 6.6 is of no significance.
S
no
S
S
Term. I0.x
Effective parameters are:
S
Term. I1.x
– P0660 (function, input terminal I0.x)
S
no
– P0661 (function, input terminal I1.x)
S
no
P0662 and P0663 are ineffective
S
S
Term. O0.x
Effective parameters are:
S
Term. O1.x
– P0680 (signal function, output terminal O0.x)
S
no
– P0681 (signal function, output terminal O1.x)
S
no
P0682 and P0683 are ineffective
No,
P0664 to P0671 (function, input terminal I4 to I11)
cannot be used
and
P0684 to P0691 (signaling function, output terminal O4
to O11)
are of no significance
S
no
P0872 = 4
––> The following option module was detected:
S
no
Optional PROFIBUS–DP3 module (from SW 3.1)
with PROFIBUS–ASIC DPC31 with PLL
S
Order No. (MLFB): 6SN1114–0NB01–0AA0
PROFI-
BUS–DP3
S
S
RS232
Permissible settings
S
no
– P0801 = 0 (RS232 interface, standard)
P0801 = 1 is interpreted just like P0801 = 0
P0802 and P0803 are of no significance
SIMODRIVE 611 universal Description of Functions (FBU) – 04.05 Edition
This should be observed for
This should be observed for
SIMODRIVE 611 universal E
SIMODRIVE 611 universal E
hex
E Siemens AG 2005 All Rights Reserved
08.02
01.99
05.00
! not 611u !

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 universal e

Table of Contents