Kpw945A4> Air Direction Adjustment Grille - Daikin FTKS L Series Engineering Data

Split, cooling only/heat pump, r-410a, inverter
Table of Contents

Advertisement

Optional Accessories
13.6 <KPW945A4> Air Direction Adjustment Grille
Before installation
Check the following parts
Installation Procedure
Selection of Installation Location
Use when installing in a location that meets the following conditions.
When installing near the border to a neighbor's house
If exhaust blows directly on passers-by because outdoor unit is instal-
led facing a road.
If exhaust blows directly on vegetation
Caution
Attach the louvers overlapping the standard grille.
Installing the louvers without the grille would allow hands to enter the fan area,
which is dangerous, so be sure to install the standard grille.
When pointing up
(1) Remove the 4 attachment screws from
the standard grille.
(2) Install the louver pointed up.
Overlap the standard grille and
screw both in together.
The attachment screws
are in the louvers.
(3)
Installation complete
238
Name
Louver
Shape
Quantity
1piece
A minimum of 100mm is needed
between the back of the outdoor
unit and any obstructions
(walls, etc.)
Installation of Louvers
(1)
(2)
(3)
Truss tapping screw
Installation manual
M4×4screws(max.7.5kW class)
M5×4screws(8.0/9.0kW class)
Space Needed for Installation
When pointing down
Remove the 4 attachment screws from
the standard grille.
Install the louver pointed down.
Overlap the standard grille and
screw both in together.
The attachment screws
are in the louvers.
Installation complete
Split Type Air Conditioners FTK(X)S-L Series
ED041204
1piece
3P089958-2C