System Interconnection (1)

System Interconnection (1)
Basic Programming (H.323, SIP)
Basic Programming (H.323, SIP)
Following table describes the basic setup for System Interconnection for H.323 and
SIP.
(Some PRG Names mentioned "H.323" but these shall use for the interconnection by SIP case.)
CD-CP00 Setup
IPLA Setup
SIP/H.323 Gate
Keeper Setup
Alias Address
Setup
SIP/H.323 System
Interconnection
Setup
System Interconnection by SIP supports only between SV8100 and S
System Interconnection by SIP supports only between SV8100 and S
© 2009 by NEC Taiwan
PRG No.
Item No.
10-12
84-26
GW No.
10-17
10-18
Alias 1
10-23
Sys No.1
Note : Default Gateway (PRG10-12-03) must be set in case of WAN (via Router).
Item
09
IPLA IP Address
10
Subnet Mask
03
Default Gateway
01
GW IP Address
01
Gate Keeper Mode
02
Gate Keeper IP Address
01
Alias Address
01
System Interconnection
02
Destination IP Address
04
Dial Number
System-A
172.16.1.10
255.255.0.0
0.0.0.0
(Note)
172.16.1.20
2 (Manual)
172.16.1.10
11
1 (Yes)
172.16.2.10
12
V8100 connection.
V8100 connection.
System-B
172.16.2.10
255.255.0.0
0.0.0.0
172.16.2.20
2 (Manual)
172.16.2.10
12
1 (Yes)
172.16.1.10
11