System Model (0X5E); Dac Filter (0X61) - Arcam SA20 Custom Installation Notes

Ip/serial programming interface and ir remote control commands
Hide thumbs Also See for SA20:
Table of Contents

Advertisement

System model (0x5E)

Request the system model.
Example
Command/response sequence to request the system model, where the
model is SA10.
Command:
0x21 0x01 0x5E 0x01 0xF0 0x0D
Response:
0x21 0x01 0x5E 0x00 0x04 0x53 0x41 0x31 0x30 0x0D

DAC Filter (0x61)

Sets or requests the DAC filter
Example
Command/response sequence to request the DAC filter where response is
Linear Phase Fast Roll Off
Command:
0x21 0x01 0x61 0x01 0xF0 0x0D
Response:
0x21 0x01 0x61 0x00 0x01 0x00 0x0D
18
COMMAND:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x5E
Dl
0x01
Data
0xF0 – Request the system model
Et
0x0D
RESPONSE:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x5E
Ac
Answer code
Dl
0x04
Data
System model in ASCII characters
Et
0x0D
COMMAND:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x61
Dl
0x01
Data
0x00 - Linear Phase Fast Roll Off
0x01 - Linear Phase Slow Roll Off
0x02 - Minimum Phase Fast Roll Off
0x03 - Minimum Phase Slow Roll Off (SA20 only)
0x04 - Brick Wall (SA20 only)
0x05 - Corrected Phase Fast Roll Off (SA20 only)
0x06 - Apodizing (SA20 only)
0xF0 - Request the current filter
Et
0x0D
RESPONSE:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x61
Ac
Answer code
Dl
0x01
Data
0x00 - Linear Phase Fast Roll Off
0x01 - Linear Phase Slow Roll Off
0x02 - Minimum Phase Fast Roll Off
0x03 - Minimum Phase Slow Roll Off (SA20 only)
0x04 - Brick Wall (SA20 only)
0x05 - Corrected Phase Fast Roll Off (SA20 only)
0x06 - Apodizing (SA20 only)
Et
0x0D