Output Temperature (0X57); Auto Shutdown Control (0X58) - Arcam SA20 Custom Installation Notes

Ip/serial programming interface and ir remote control commands
Hide thumbs Also See for SA20:
Table of Contents

Advertisement

Output temperature (0x57)

Request the temperature of the output stage.
Example
Command/response sequence for requesting the temperature of the output
where the result is 75 degC:
Command:
0x21 0x01 0x57 0x01 0xF0 0x0D
Response:
0x21 0x01 0x57 0x00 0x01 0x4B 0x0D

Auto shutdown control (0x58)

Enable or disable the signal sense auto shutdown feature
Example 1
Command/response sequence, the signal sense auto shutdown timeout has
been set to 60 minutes:
Command:
0x21 0x01 0x58 0x01 0x02 0x0D
Response:
0x21 0x01 0x58 0x00 0x01 0x02 0x0D
Example 2
Command/response sequence, the signal sense auto shutdown has been
disabled:
Command:
0x21 0x01 0x58 0x01 0x00 0x0D
Response:
0x21 0x01 0x58 0x00 0x01 0x00 0x0D
COMMAND:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x57
Dl
0x01
Data
0xF0 – Request output temperature
Et
0x0D
RESPONSE:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x57
Ac
Answer code
Dl
0x01
Data
0x?? – Temperature in deg C in hex, e.g. 75degC = 4B
Et
0x0D
COMMAND:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x58
Dl
0x01
Data
0x00 – Disable (Default)
0x01 – 30 min
0x02 – 1 hour
0x03 – 2 hours
0x04 – 4 hours
0xF0 – Request timeout status
Et
0x0D
RESPONSE:
Byte:
Description:
St
0x21
Zn
Zone number
Cc
0x58
Ac
Answer code
Dl
0x01
Data
0x01 – 30 min
0x02 – 1 hour
0x03 – 2 hours
0x04 – 4 hours
Et
0x0D
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sa10

Table of Contents