Chamberlain LiftMaster Professional CB124 Instructions Manual

Hide thumbs Also See for LiftMaster Professional CB124:

Advertisement

Quick Links

de
Anleitungen CB124
Instructions CB124
fr
Instructions CB124
en
Návody CB124
cz
Instrucciones CB124
es
Instruktioner CB124
sv
Útmutatók CB124
hu
hr
Upute CB124
Istruzioni CB124
it
Instruktie CB124
nl
Obrázky CB124
sk
Instrukcja CB124
pl
Chamberlain GmbH
Alfred-Nobel-Strasse 4
D-66793 Saarwellingen
www.chamberlain.de
info@chamberlain.de
0678
AT/BA/BE/BG/CH/CY/CZ/DE/DK/ES/
FR/GB/GR/HR/HU/IE/IS/IT/LU/MT/NL
NO/PL/PT/RO/RU/SE/SI/SK/TR/YU

Advertisement

Table of Contents
loading

Summary of Contents for Chamberlain LiftMaster Professional CB124

  • Page 1 Anleitungen CB124 Instructions CB124 Instructions CB124 Návody CB124 Instrucciones CB124 Instruktioner CB124 Útmutatók CB124 Upute CB124 Istruzioni CB124 Instruktie CB124 Obrázky CB124 Instrukcja CB124 Chamberlain GmbH Alfred-Nobel-Strasse 4 D-66793 Saarwellingen www.chamberlain.de info@chamberlain.de 0678 AT/BA/BE/BG/CH/CY/CZ/DE/DK/ES/ FR/GB/GR/HR/HU/IE/IS/IT/LU/MT/NL NO/PL/PT/RO/RU/SE/SI/SK/TR/YU...
  • Page 2: Table Of Contents

    TOPIC PAGE SAFETY RULES ..................1 TECHNICAL DATA OF MOTOR CONTROL .
  • Page 3: Safety Rules

    WARNING / ATTENTION IMPORTANT FITTING AND OPERATING INSTRUCTIONS PLEASE START BY READING THESE IMPORTANT SAFETY RULES This safety alert symbol means "Caution" - failure to comply with such an instruction involves risk of personal injury or damage to property. Please read these warnings carefully. This gate drive mechanism is designed and tested to offer appropriately safe service provided it is installed and operated in strict accordance with the following safety rules.
  • Page 4: Technical Data Of Motor Control

    TECHNICAL DATA Voltage: 230V~ ±10% 50Hz Transformer: 230V/24V, 150VA Output Motor: 24V/DC Consumption max.: max. 400W (in operation) Consumption Standby: max. 4 Watt (without accessories) Supply accessories: 24VDc / 600mA max. Operating temperature: -25ºC ÷ 55ºC Modes: Standard, Automatic Measurements: 250x75mm (without box) Measurements Box: ca.
  • Page 5: Recommended Procedure

    RECOMMENDED PROCEDURE: Fasten exterior installation box to wall, after previously measuring required distances and establishing correct position of drill-holes (Hardware not included). Baseplate for transformer is already pre-assembled (A). Push fastening clips in designated holes (B) . Push controlboard on to fastening clips (C). Fasten transformer on to baseplate using the large screw and large washer (D).
  • Page 6: Wiring Of Control / Summary

    WIRING OF CONTROL / SUMMARY a) start with 230Volts supply cable. Run cable through large cable bushing on the lefthand side. b) Attach cable eye to ground wire. Then connect ground wire to base plate with washer and nut (exactly as shown in picture detail). Connect all other cables to control.
  • Page 7: Wirind Diagramm

    WIRING DIAGRAM Model Model ANT4X-1LM 203285 433Mhz = 22cm 868Mhz = 11cm INPUT 24VAC Model 801221 = 433Mhz Model 41A6498-1 = 868Mhz 250V/2A STOP EDGE PHO 3 LEARN 250V/2A POWER SUPPLY 230VAC/50Hz EDGE BRN GRN WHT YEL BRN GRN WHT YEL PHOTO STOP MOTOR...
  • Page 8: Description Function

    DESCRIPTION FUNCTION DESCRIPTION OF LED´S (LIGHT EMITTING DIODE) connector L 230V supply DESCRIPTION COLOUR STATUS connector N 230V supply Stop green Stop Switch 30VDC connector for a battery kit +/- ON: Stop Active CM475 + 041ADBL-0115 OFF: OK Motor MASTER motor 1 (master opens first) red/blue (Requires wire bridge if no Motor SECOND...
  • Page 9: Backup Battery

    ACCESSORIES (also refer to wiring diagram) BACKUP BATTERY (OPTIONAL) MODEL: CM475 (24V/AC) The terminals serve to reload an externally installed storage battery. The integrated recharger is loaded and in case of power failure the battery provides power. A new fully charged storage battery may provide power for more than 24 hours.
  • Page 10: Photocells

    The photocell is mounted on the wall using + + + small screws and wall plugs. To enable the “Automatic Closing” function, the Chamberlain failsafe photocell must be installed. The Chamberlain failsafe system (2-cable system) has small LEDs (light) that can be seen from the outside on both sides to indicate the status of the photocell.
  • Page 11: Loop Detector Usage

    LOOP DETECTOR Jumper LOOP / EDGEmust be plugged Loop detectors react to metal and the most common use is for cars or trucks but not for bikes or pedestrians. Exit loop / Gate Opening Loop An exit loop is behind the gate and opens the gate when closed, keeps it open or re-opens the gate.
  • Page 12: Jumper Settings

    JUMPER SETTINGS 1 / 2 Motor Select if 1 or 2 motors are connected to the control board FREE: 2 Motors connected PLUGGED: 1 Motor connected OPEN/STEP Changes the programming and reaction of the gate on commands. For the use with loop detectors please refer to the loop detector instruction first.
  • Page 13: Initial Operation Basic Setting

    INITIAL OPERATION BASIC SETTING Proceed step by step. If you are not sure, start again at the beginning. Take sufficient time to make these settings. Are all components required for operation connected? Motors, photocells, safety contact strip, stop switch. Make sure that nobody is present in the range of the gates. Close the gate/s and attach motor/s.
  • Page 14 PROGRAMMING TRAVEL DISTANCES “SIMPLE I” NOTE: End stops must be available in CLOSED and OPEN modes. Wings must be closed Press P1 until wing / motor 1 starts opening (learn-LED flashes) Automatic programming starts (slow travel) Wing 1 moves to the stop in OPEN position Wing 2 moves to the stop in OPEN position Then wing 2 moves to the stop in CLOSE position.
  • Page 15: Timer To Close (Auto-Close)

    NOTE: If one wing reaches a stop and button P1 is not pressed, then the motor moves towards the stop and stores this position automatically. COMPLETION OF INSTALLATION / PROGRAMMING Once the travel distances are programmed, the remote controls can be programmed as well. (Refer to PROGRAMM / DELETE REMOTE CONTROLS).
  • Page 16: Diagnosis Led

    INDICATION OF THE DIAGNOSIS LED The LED diagnostics show the first upcoming issue. If several issues are existing the LED diagnostics may not show them. Indication Description Remedy 1x blinking Motor 1 has insufficient connection to control board Cables not wired or badly connected. Control board does not see motor sensor.
  • Page 17: Faqs

    The optimum location of the aerial is as high as possible in all cases. An appropriate aerial with installation kit can be obtained from Chamberlain as an accessory. The gate must follow a slope.