Download Print this page

Specification - LG AMNW18GECA0 Svc Manual

Exploded view
Hide thumbs Also See for AMNW18GECA0:

Advertisement

1. Specification

Indoor
Model
Power supply
Current (Cooling/Heating)
Fan
Motor type
Fan type
Piping
Liquid
connections
Gas
Dimensions
(W*H*D)
Referigerant control
Power&transmission cable
No. x mm
Note:
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80.6°F) DB/19°C(66.2°F) WB
- Outdoor Temperature 35°C(95°F) DB/24°C(75.2°F) WB
Heating: - Indoor Temperature 20°C(68°F) DB/15°C(59°F) WB
- Outdoor Temperature 7°C(44.6°F) DB/6°C(42.8°F) WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without prior notice for purpose of improvement.
Copyright ©2014 LG Electronics. Inc. All right reserved.
Only for training and service purposes
AMNW18GECA0
[MS18SQ NC0]
Ø/V/Hz
1/220-240/50
A
Cross Flow Fan
mm(inch)
mm(inch)
12.70(1/2)
mm
1030*325*250
inch
40.6*12.8*9.84
2
4*1.0(Including Earth)
6.6/7.3
BLDC
6.35(1/4)
EEV(in Outdoor Unit or BD)
- 2 -
AMNW24GECA0
[MS24SQ NC0]
1/220-240/50
9.8/10.4
BLDC
Cross Flow Fan
6.35(1/4)
12.70(1/2)
1030*325*250
40.6*12.8*9.84
4*1.0(Including Earth)
Conversion Formula
kW = Btu/h x 0.0002931
cfm = CMM x 35.3
LGE Internal Use Only

Advertisement

loading

This manual is also suitable for:

Ms18sq nc0Amnw24geca0Ms24sq nc0