Venting; Setting Up For Left Or Right Exhaust; Vent Installation Requirements - Montigo E38-PV Installation Operation & Maintenance

Power-vented
Table of Contents

Advertisement

E38-PV Gas Fireplace
Right or Left V
Right or Left V
Right or Left Vent Exhaust
Right or Left V
Right or Left V
The fireplace may ventout the right or left hand side. To convert:
1. Lift off upper housing cover.
2. Disconnect flexible vent from the venter motor.
3. Remove the four(4) machine screws that hold the venter motor
secure and rotate the motor 180° . Replace & tighten the four(4)
machine screws to secure the motor in place.
4. Remove the four(4) sheet metal screws that hold the fan plate
secure. Remove the four(4) sheet metal screws that hold the vent
exhaust plate secure. Reverse the two plates and re-install all
screws. Ensure that the screws are tightened properly.
5. Re-connect the flexible vent, ensure that a goodconnection is
made.
6. Replace upper housing cover.
Upper housing cover
Flexible vent
f i r e - p a r t s . c o m
4 x Machine screws
Figure 8. Right hand exhaust.
Upper housing cover
Flexible vent
Venter Motor
Figure 9. Left hand exhaust
Page 6
Page 6
Page 6
Page 6
Page 6
Installation
ent Exhaust
ent Exhaust
ent Exhaust
ent Exhaust
Vent exhaust plate
Venter motor
4 x Machine screws
Vent Installation
Installation Requirements
E38-PV fireplaces are certified for use with Montigo Power Vent
n
components and Standard Series (4" / 7") venting components
0" clearance to combustibles for vent pipes
n
Use only certified Montigo vent components. (Use of other parts
n
will void the Montigo warranty, and may impede the operation of
the fireplace.)
All joints must be secured with a minimum of two screws per joint
n
and sealed with high temp silicone
The exhaust portion of avent termination must not be recessed in
n
walls or siding
Horizontal runs with solid pipe must be supported by a minimum
n
of two supports per horizontal run. A minimum of one screw on
each side of support is also required
Flex vent sections may be stretched up to twice their compressed
n
length (i.e. a 6' section may be stretched to 12')
7" flex vent requires
min. opening of 7 1/2" x 7 1/2"
Power vent drop
termination
Std. MTO
termination
0" Clearance
to combustibles
for venting
Figure 10. Typical vent configurations.
7 1/2
7 1/2
Left or right exhaust
Max. Vent length: 60 feet
Min. Vent length: 3 feet
Part No. XM0500