Pilot Burner Adjustment
1. Determine which pilot is installed in the fireplace based on figures
25a and 25b.
2. Locate Pilot Adjustment Screw. (See figures 24a, 24b, and 24c.)
3. Adjust pilot key to provide properly sized flame. (See figure 25a or
25b).
4. Replace pilot adjustment cap.
5. After installing or servicing, leak test with a soap solution with main
burner on. Coat pipe and tubing joints, gasket etc. with soap solution.
Bubbles indicate leaks. Tighten any areas where the bubbles
appear until the bubbling stops completely.
f i r e - p a r t s . c o m
Figure 25a. SIT Pilot Burner used on the EP28-F2 model.
Figure 25b. PSE Pilot Burner used on the EP28-S2 model.
XG0318
Maintenance
The following is a troubleshooting chart of possible problems:
PROBLEM
Noisy Pilot Flame
Pilot won't ignite
Main burner will
not light
SP28-F2 Modular Series Fireplace
Troubleshooting
CORRECTIVE ACTION
Remove pilot adjuster cap, located on
the gas control valve. Flame is
decreased by turning adjustment screw
clockwise.
Disconnect remote wires and try to light
pilot. If pilot now works, remote
connections are faulty. Check wiring
diagram
24a/b/c.
figure
1. Check wiring (see figure 24a/b/c)
2. Check wall switch for proper
connection.