Maintenance - Montigo SP28-F2 Installation Operation & Maintenance

5" b-vented gas fireplaces
Hide thumbs Also See for SP28-F2:
Table of Contents

Advertisement

SP28-F2 Modular Series Fireplace
CAUTION
n
Fireplace gas control must be in the "OFF" position and pilot and
main burners extinguished when cleaning appliance with a
vacuum.
n
Glass and logs can get very hot. Handle only when cool.
General
n
Have the fireplace installation inspected yearly, including a visual
check of the vent system, the burner and the pilot flame. For your
convenience a 1/8" manifold pressure tap is supplied on the gas
valve for a test gauge connection. See Figure 24a, 24b, and 24c.
n
For Natural Gas this appliance requires a minimum inlet pressure of
5.5" W.C. and a manifold pressure of 3.5" W.C.
n
For Propane Gas this appliance requires a minimum inlet pressure
of 11" W.C. and a manifold pressure of 10" W.C.
n
Always keep the fireplace area clear and free of combustible
materials, as well as gasoline and other flammable vapours and
f i r e - p a r t s . c o m
liquids.
n
Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance
and to replace any part of the control system and any gas control
which has been under water.
Cleaning
When the fireplace is first activated, there may be some smoking and a
visible film may be left on the glass doors. This is a normal condition, and
is the result of burning the protective coatings on new metal.
n
Glass must be cleaned periodically to remove any film (a normal bi-
product of combustion) which may be visible. Handle the door
carefully, and clean it with non-abrasive glass cleaners. One of the
most effective products is Kel Kem.
n
Silicone seals on inner door during initial firing will "off gas", leaving
a visual deposit of a white substance on combustion chamber walls.
This can easily be removed by following the steps described above.
n
Use a vacuum cleaner or whisk broom to keep the control
compartment, burner, and firebox free from dust and lint.
n
Logs may be cleaned periodically to remove soot.
WARNING:
Do not attempt to clean glass when hot.
Do not clean glass with abrasive materials as any glass etching
may cause premature glass failure.
Page 12

Maintenance

S pill S w itch
Figure 24a. Honeywell gas valve used on the EP28-F2.
Figure 24b. Robertshaw gas valve used on the EP28-F2.
Figure 24a. Honeywell VS8510E gas valve used on the EP28-S2.
Gas Control Valve