List Of Jointly Supported At-Commands; Standard V.25Ter At Commands; Table 5-1: Standard V.25Ter At Commands - Siemens TC35i Migration Manual

Cellular engine
Hide thumbs Also See for TC35i:
Table of Contents

Advertisement

TC35i: Migration from TC35 to TC35i
P R E L I M I N A R Y
5.2

List of jointly supported AT-commands

AT-commands listed in the tables below are supported by both TC35i and TC35. Command
defaults, however, may differ.
NOTE: Many commands are available only after the PIN has been entered. For a full list, please refer to
respective AT reference manuals.

Standard V.25ter AT Commands

5.2.1

Table 5-1: Standard V.25ter AT commands

#
AT
1 A/
Repeat previous command line
2 +++
Switch from data mode to command mode
3 AT\Qn
Flow control
Differing implementation
TC35i
AT\Qn included within user profile. See comments under AT&W.
4 ATA
Answer a call
5 ATD
Mobile originated call to dial a number
Differing implementation
TC35i
International calls to be dialled exclusively starting with "+", i.e. "00" at the beginning of a
dialling string will not be translated into a "+".
6 ATD><mem><n> Originate call to phone number <n> in memory <mem>
7 ATD><n>
Originate call to phone number selected from active memory
8 ATD><str>
Originate call to phone number in memory with corresponding field
9 ATDI
Mobile originated call to dialable ISDN number <n>
10 ATDL
Redial last telephone number used
11 ATE
Enable command echo
Differing parameters
TC35i
MUX: Echo is disabled at the start of MUX mode and
is not available on logical channels, ATE1 responds
with ERROR
12 ATH
Disconnect existing connection
13 ATI
Display product identification information
14 ATI[value]
Display additional identification information
15 ATL
Set monitor speaker loudness
16 ATM
Set monitor speaker mode
17 ATO
Switch from command mode to data mod
18 ATQ
Set result code presentation mode
19 ATP
Select pulse dialling
20 ATS0
Set number of rings before automatically answering the call
Differing implementation
TC35i
ATS0 applies to incoming voice calls as well.
22 ATS2
Escape code sequence
23 ATS3
Write command line termination character
24 ATS4
Set response formatting character
25 ATS5
Write command line editing character
26 ATS6
Set pause before blind dialling
27 ATS7
Set number of seconds to wait for connection completion
Differing implementation
TC35i
ATS7 applies to voice calls as well.
28 ATS8
Set number of seconds to wait for comma dial modifier
29 ATS10
Set disconnect delay after indicating the absence of data carrier
30 ATS18
Extended error report
31 ATT
Select tone dialling
TC35_TC35i_MIG_01_V01.01
Command
TC35
MUX: Echo is available on logical channels and is
initially enabled only on main (data) MUX channel.
TC35
ATS0 applies only to incoming data or fax calls.
TC35
ATS7 applies only to data calls.
29.1.2003
TC35
-
TC35
-
Page 23 of 34

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tc35

Table of Contents