Samsung RAC Series Technical Data Book page 24

Single rac for america low ambient, r410a, cooling only system
Table of Contents

Advertisement

8. Electrical Wiring Diagram
Outdoor Unit
Outdoor Unit
AC030MXSCCC/AA, AC036MXSCCC/AA
MAIN PCB
Printed circuit board(MAIN)
INVERTER
Printed circuit board(INVERTER)
PCB
EMI
Printed circuit board(EMI)
NOTE
• This wiring diagram applies only to the outdoor unit.
• Symbols show as follow: blk: black, red: red, blu: blue, wht: white, yel: yellow, brn: brown, sky: skyblue, grn: green
• For connection wiring indoor-outdoor transmission F1-F2
: Protective earth(SCREW)
24
RED
RED
EEV
Electronics Expansion Valve
M-BLDC
BLDC Motor
OLT-TH(200K)
Thermistor OLP
BELT HEATER
Comp Belt Heater
FUSE HOLDER ( 500V 15A )
DIS-TH(200K)
Thermistor DISCHARGE
OUT-TH(10K)
Thermistor AMBIENT
COND-TH(10K)
Thermistor CONDENSOR

Hide quick links: