Operating

7.4 Current measurement data

7.3

Retrieve module configuration

The Wireless Communication Module can send the parameters of the module configuration in
a .txt file by email or to a FTP(S) server (depending on parameter P52). To request the .txt file,
please send the following command.
Syntax:
● RetrieveConf;[PIN];[EMAIL ADDRESS];
If email or SMTP(S) protocol is selected
● RetrieveConf;[PIN];[FTP(S) SERVER];
If FTP(S) protocol is selected
Example:
RetrieveConf;1000;a@mail.com;
Note
The Wireless Communication Module will not send a response SMS.
Note
Passwords are not included in the configuration email.
7.4
Current measurement data
This command retrieves the current MAG 8000 measurement data by SMS.
Request syntax:
GET_MEASUREMENT_DATA;
Response syntax:
[IDENTIFIER] [TIMESTAMP]
FL [FLOWRATE VALUE] [FLOWUNIT]
T1 [TOT1]
T2 [TOT2]
T3 [TOT3]
VU [TOTALIZER UNIT]
A1 [VALUE OF ANALOG INPUT 1] [UNIT OF ANALOG INPUT 1]
A2 [VALUE OF ANALOG INPUT 2] [UNIT OF ANALOG INPUT 2]
BT [BATTERY CAPACITY] %
AL [ALARM/WARNING INDEX] [ALARM/WARNING INDEX]
TT [TRANSMITTER TEMPERATURE] C
Response example:
123456H123 2017-09-12 13:25
FL 20 m
T1 24.2
T2 32.34
T3 35.215
VU m
52
3
/h
3