PT-DZ6710U / PT-DZ6710E / PT-DZ6700U / PT-DZ6700E / PT-DW6300US / PT-DW6300ES / PT-D6000US / PT-D6000ES
10.2. Removal of Upper Case
(1)
Turn the lens cover counterclockwise and remove.
(2)
Remove the projection lens.
1. Fully turn the projection Lens counterclockwise.
2. While pressing the lens release button, turn the projection
lens counterclockwise in addition.
3. Remove the projection lens.
(3)
Loosen the 1 screw until it idles, then remove the lamp unit
cover.
Note:
· The lamp unit cover is connected to the main unit with
the connector. Be careful when removing it.
(4)
Unscrew the 5 screws and remove the upper case.
Note:
· Confirm the lens release button actuates correctly when
you reassemble the upper case as it was.
26