Panasonic PT-DZ6710U Service Manual page 223

Dlp based projector
Hide thumbs Also See for PT-DZ6710U:
Table of Contents

Advertisement

3.2.
SELF CHECK Information
Hexadecimal
Remarks
Response (Callback)
In the period when the command can be accepted
Hexadecimal
Acceptability
SECURITY
Yes
Parameters 1 (*2, *3, *4, *5)
Bit
31
Bit
Name
bit31
Main CPU error
bit30
Fan error
bit29
Optical module
temperature error
bit28
Intake air temperature
error
bit27
Lamp surroundings
temperature error
bit26
ACF installation error
bit25
LAMP2 time error
(Shutdown)
bit24
LAMP1 time error
(Shutdown)
bit23
LAMP2 turning ON
failure
bit22
LAMP1 turning ON
failure
bit21
Aperture error
bit20
Shutter error
bit19
Optical module
thermosensor
disconnected
bit18
Intake air thermosensor
disconnected
bit17
Lamp surroundings
thermosensor
disconnected
bit16
Warning of battery for
clock
02h
*1
FEh
STX
ID
Command
02h
*5
FEh
STX
ID
STNDBY
ECO STNDBY
Yes
Yes
*2
24
23
Description
The main CPU circuit is abnormal. It is a breakdown when not
recovering even if the power is turned on again.
The fan and/or fan drive circuit is abnormal. It is a breakdown when
not recovering even if the power is turned on again.
Abnormally high temperature is detected inside this projector and the
shutdown has occurred.
- The ventilation holes may be closed.
- The ambient temperature in the place of use may be too high.
- The air filter may accumulate dust.
The air filter has not been installed properly.
The lamp ON time exceeds specified cumulative usage time, and
becomes a period when the lamp unit is replaced.
It fails in the turning ON the lamp.
- The power may have been turned on straight away after it was
turned off.
Not used in this projector
It fails in the operation of the shutter. It is a breakdown when not
recovering even if the power is turned on again.
The thermosensor in this projector has breaking of wire, or connector
A10 is disconnected.
The intake air thermosensor has breaking of wire, or connector A9 is
disconnected.
The lamp surroundings thermosensor has breaking of wire, or
connector R34 is disconnected.
It is necessary to replace the battery (CR2032) on the battery holder
B3780.
03h
ETX
*2
*3
*4
Parameters 1
NO SIGNAL
SHUTTER
Yes
Yes
*3
16
15
79/80
*5
*6
*7
Parameters 2
FREEZE
TEST PATTERN
Yes
Yes
*4
8
7
*8
*9
03h
ETX
REMOTE2
Yes
*5
0
Condition of
Clear Bit
Power ON
Power ON
Power ON
Power ON
Power ON
Filter reset
or Power ON
LAMP2 reset
LAMP1 reset
LAMP2 ON
success or
Power ON
LAMP1 ON
success or
Power ON
Power ON
MAIN
POWER ON
MAIN
POWER ON
MAIN
POWER ON
Battery
replacement

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents