Panasonic PT-DZ6710U Service Manual page 18

Dlp based projector
Hide thumbs Also See for PT-DZ6710U:
Table of Contents

Advertisement

PT-DZ6710U / PT-DZ6710E / PT-DZ6700U / PT-DZ6700E / PT-DW6300US / PT-DW6300ES / PT-D6000US / PT-D6000ES
3. Generates a hash value (message digest) from "admin1:panasonic:1aa6c14e" by using the MD5.
"admin1" = Administrator authority user-name
"panasonic" = Password corresponding to "admin1"
Hash value = "01466bc27ed8c0b7e607471580c55953"
4. Transmits the command.
Transmission data = "01466bc27ed8c0b7e607471580c5595300QPW" + (CR)
5. Receives a response.
Reception data = "00000" + (CR)
6. Disconnects the connection with the projector.
Example 2: Query FILTER INFORMATION - RUNTIME "QFI:0"
1. Connects to the projector.
IP = 192.168.0.8, Port number = 1024
2. Receives a response.
Response = "NTCONTROL 1 0bda3637" + (CR)
"0bda3637" = 8 bytes random characters
3. Generates a hash value (message digest) from "admin1:panasonic:0bda3637" by using the MD5 .
"admin1" = Administrator authority user-name
"panasonic" = Password corresponding to "admin1"
Hash value = "a5bf5df3e35c4802a6cdf21880f69093"
4. Transmits the command.
Transmission data = "a5bf5df3e35c4802a6cdf21880f6909300QFI:0" + (CR)
5. Receives a response.
Reception data = "00 (SP) (SP) 142" + (CR)
6. Disconnects the connection with the projector.
5.2.2.
When WEB CONTROL Admin Password is not set (Unprotected Mode)
5.2.2.1.
Connection
1. Access IP address and the port number (default = 1024) of the projector, then connect to the projector with them.
IP address and the port number can be accessed from the menu of the projector.
· IP address: MAIN MENU → NETWORK → NETWORK STATUS
· Port number: MAIN MENU → NETWORK → NETWORK CONTROL → COMMAND PORT
2. Receive a response message.
Response Message
Mode: 0 = Unprotected mode
5.2.2.2.
Method of Command Transmission
Transmits command by the following format.
Transmission Data
Reception Data
Data section
"NTCONTROL"
(ASCII character string)
9 bytes
Header
´0´
´0´
0x30
0x30
1 byte
1 byte
Header
´0´
´0´
0x30
0x30
1 byte
1 byte
Space
Mode
´ ´
´0´
0x20
0x30
1 byte
1 byte
Data section
Control command
(ASCII character string)
Undefined length
Data section
Control command
(ASCII character string)
Undefined length
18
End character
(CR)
0x0d
1 byte
End character
(CR)
0x0d
1 byte
End character
(CR)
0x0d
1 byte

Hide quick links: