Interfaces

3.2 DRIVE-CLiQ interfaces

3.2
DRIVE-CLiQ interfaces
DRIVE-CLiQ interfaces
All SINAMICS S120 drive system components, including the motors and encoders, are
interconnected by a shared serial interface called DRIVE-CLiQ. The standardized cables and
connectors reduce the variety of different parts and cut storage costs.
DRIVE-CLiQ has the following properties:
● Automatic detection of components by the control unit
● Standardized interfaces to all components
● Uniform diagnostics down to the components
● Complete service down to the components
● 24 V / 450 mA per DRIVE-CLiQ interface are provided for the connection of encoders and
Position of connectors
Figure 3-1
42
measuring systems.
Note:
The DRIVE-CLiQ cables with 24 V supply should be used only for components that
require this (e.g. motors with a DRIVE-CLiQ interface).
B
8
1
A
Position of the DRIVE-CLiQ interfaces on the D4x5
SIMOTION D4x5
Manual, 02/2012