Power Supply Of Digital Outputs - Siemens SIMOTION D4 5 Series Manual

Table of Contents

Advertisement

6.3.3.3

Power supply of digital outputs

Table 6- 3
Terminal block X424
Terminal
+
+
G
G
Table 6- 4
X424 wiring
Features
Connectable cable types and conductor cross-sections
Rigid, flexible
With end sleeve, without plastic sleeve
With end sleeve, with plastic sleeve
Stripped length
Tool
Tightening torque
Features
Two "+" terminals and two "G" terminals are available. These are jumpered in the connector.
This loops through the power supply.
This power supply is only required for the digital outputs.
The option slot of the D4x5 Control Unit also provides the following power supplies:
● Electronic power supply of the TB30
● Supply of the analog inputs and outputs.
The power supply of the digital outputs and the electronic power supply of the Control Unit
are isolated.
SIMOTION D4x5
Manual, 02/2012
Function
Power supply
Power supply
Ground
Ground
Supplementary system components
Technical specifications
Voltage: DC 24 V (20.4 V–28.8 V)
Max. power consumption: 4 A
Max. power consumption per digital output: 0.5 A
Max. current via bridges in the connector: 20 A
Type
0.08 mm
to 2.5 mm
2
0.5 mm
to 2.5 mm
2
0.5 mm
to 1.5 mm
2
7 mm
Screwdriver 0.6 x 3.5 mm
0.5 to 0.6 Nm
6.3 TB30 terminal board
2
2
2