Procedure: Install A Connection Module X In Two Ons 15252 Mcus; Figure 3-27 Side View Of A Cmx Module - Cisco ONS 15200 Series Installation, Setup & User Manual

Table of Contents

Advertisement

Chapter 3
Installation
Carefully slide the TM into the passive optical shelf. Be sure the groove on the back of the TM connects
Step 2
with the passive optical shelf crossbeam.
Push down on the TM retainer button located on the TM front panel and snap the TM into place.
Step 3
Step 4
If applicable, repeat Steps

Procedure: Install a Connection Module X in Two ONS 15252 MCUs

Note
Use this procedure if you are using two or more installed assembled-to-order (ATO) MCUs.
Step 1
Disconnect the MU duplex connector from the TM you will replace.
Put protective caps on the MU duplex connector.
Step 2
Step 3
Remove a TM module from the passive optical shelf of the first MCU.
Position one side of the CMX
Step 4
was removed.

Figure 3-27 Side view of a CMX module

Step 5
Carefully insert the half CMX into the passive optical shelf. Be sure the groove on the back of the module
interlocks with the crossbeam located in the passive optical shelf.
Step 6
Snap the CMX into place by pushing the retainer located at the bottom of the CMX.
Step 7
Remove the dust plugs located on the CMX duplex MU-MU adapter.
78-13765-01
1–3
for the other TM.
(Figure
3-27) in the passive optical shelf of the first MCU where the TM
Cisco ONS 15200 Installation, Setup, and Test Manual
3-37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15201Ons 15252

Table of Contents