Looper-to-needle clearance in sewing direction

.05.12
Requirement
In sewing direction there must be a cleaance of approx. 0.1 mm between looper point
and needle.
Fig. 1 - 12
● Turn the balance wheel until the looper point coming from the right reaches the left side
of the needle.
● Align looper unit 1 (screw 2) according to the requirement.
2
If a clearance of 0.1 mm cannot be obtained, the setting of the eccentric bea-
ring stud 3 can be corrected. In this case the looper height and angle must be
checked, see Chapter 1.05.11 Looper height and looper angle.
0,1 mm
2
1
Adjustment