Heated Hose Connections
1. Attach the right-hand thread end of the air hose
(AA) to the gun air regulator (T).
2. Attach the left-hand thread end of the air hose to the
air whip hose (L).
3. Attach the other end of the air whip hose (L) to the
air inlet at base of the gun.
4. Attach gun swivel (J) to the gun fluid inlet.
T
AA
F
. 5. Hose Setup
IG
312798J
Z
5. Attach one end of the fluid whip hose (K) to the gun
swivel and the other end to the manifold (68).
6. Attach one blue fluid hose to the manifold (68) and
to the back pressure regulator (84).
7. Attach the other blue fluid hose to the manifold (68)
and to the filter (6) outlet.
8. Apply lens cover to both regulator gauge lenses.
9. Verify that suction hose fittings and drain hose fit-
tings are tight.
84
Z
Installation
6
H
J
L
K
68
ti13167b