Maintenance

Maintenance
Preventive Maintenance
Schedule
The operating conditions of your particular system
determine how often maintenance is required. Establish
a preventive maintenance schedule by recording when
and what kind of maintenance is needed, and then
determine a regular schedule for checking your system.
Replace lens covers on regulator gauge lenses when
dirt makes gauges difficult to read.

Tighten Threaded Connections

Before each use, check all hoses for wear or damage.
Replace as necessary. Check that all threaded connec-
tions are tight and leak-free.

Flush the Pump

Read all Warnings. Follow all Grounding instruc-
tions. See page 17.
Flush the pump:
Before first use
When changing colors or fluids
Before repairing equipment
Before fluid dries or settles out in a dormant pump
(check the pot life of catalyzed fluids)
At the end of the day
Before storing the pump.
Flush at the lowest pressure possible. Flush with a fluid
that is compatible with the fluid you are pumping and
with the wetted parts in your system. Check with your
fluid manufacturer or supplier for recommended flushing
fluids and flushing frequency.
1. Follow Pressure Relief Procedure, page 20.
2. Be sure the ES ON/OFF lever is turned to OFF.
24
3. Remove the tip guard and spray tip from gun. Refer
to separate gun manual.
4. Place siphon tube in grounded metal pail containing
cleaning fluid.
5. Set pump to lowest possible fluid pressure, and start
pump.
6. Hold a metal part of the gun firmly to a grounded
metal pail.
7. Units with runaway protection only: enable the
prime/flush function by pushing the prime/flush but-
ton on the DataTrak.
8. Trigger gun. Flush system until clear solvent flows
from gun.
9. Units with runaway protection only: disable the
prime/flush function by pushing the prime/flush but-
ton on the DataTrak.
10. Follow Pressure Relief Procedure, page 20.
11. Clean the tip guard, spray tip, and fluid filter element
separately, then reinstall them.
12. Clean the inside and outside of the suction tube.

Wet Cup

Fill the wet cup one-half full with Graco Throat Seal Liq-
uid (TSL). Maintain level daily.
312798J