Component
Generator
Circuit Diagram
G
MS 661, MS 661 C-M
Ohmmeter connection
(use either test lead)
Lead 1
Lead 2
Connector
Ground
on
generator
wire
1
4
2
5
3
Resistance Ω
If faulty
Spec.
Actual
Cause
0.6
0.5 - 1
Generator OK
-
Break in wire,
generator damaged
0
Short circuit –
damaged insulation
G = Generator
1 = Rear handle
2 = Handlebar
3 = Heater switch
4 = Thermostatic switch
5 = Heating element (carburetor)
Remedy
Install new
generator
repair insulation