Panasonic KX-TG7120FXT Service Manual page 42

Table of Contents

Advertisement

KX-TG7120BXS/KX-TG7120BXT/KX-TGA711CXS/KX-TGA711CXT
Items
(O)
Sensitivity Receiver
Confirmation
(P)
Timing Confirmation
(Q)* RSSI Level Confirmation
(R) Power RAMP Confirma-
tion
(S) Audio Check and Confir-
mation
(T) SP phone Audio Check
and Confirmation
9.3.2.
Troubleshooting for Speakerphone
When the customer's telephone line corresponds to the following conditions, and the transmission signal of SP-Phone is inter-
rupted, performing the next set up to a cordless handset will improve it to some extent.
Conditions
1. When customer's line has less line loss.
ex.) The customer is using optical fiber, ISDN terminal adaptor, or PBX.
In this case, receiving signal is strong and it may affect transmission signal.
2. When the other party is talking from noisy place.
ex.) The other party is using cellular phone. The background noise is very loud.
In this case, the noise from the other party (i.e. surrounding noise) may affect transmission signal.
Setting Method
• Change the address of EEPROM (0144) from 00 to 01.
Check
Point
-
Follow steps 1 to 3 of (K).
4.Set DECT tester power to -88 dBm.
5.Confirm that the BER is < 1000 ppm.
-
Follow steps 1 to 3 of (K).
4.Confirm that the Timing accuracy is < ± 2.0 ppm.
-
Follow steps 1 to 3 of (K).
4.Set DECT tester power to -81 dBm.
5.Execute the command "readrssi".
6.Confirm that the returned value is 1C ± 8 (hex).
7.Set DECT tester power to -63 dBm.
8.Execute the command "readrssi".
9.Confirm that the returned value is 25 ± 8 (hex).
-
Follow steps 1 to 3 of (K).
4.Confirm that Power RAMP is matching.
-
1. Link to BASE which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 40 mA.
3. Input -45 dBm/1 KHz to MIC and measure Line output level.
4. Confirm that the level is -8.5 dBm ± 2 dBm and that the distortion level is < 5 %
at TEL Line (600 Ω Load).
5. Input -20dBm/1KHz to Line I/F and measure Receiving level at REV1 and
REV2.
6. Confirm that the level is -21 dBm ± 2 dBm and that the distortion level is < 5 %
at Receiver. (vol = 2)
-
1. Link to Base which is connected to Line Simulator.
2. Set line voltage to 48 V and line current to 40 mA.
3. Set the handset off-hook using SP-Phone key.
4. Input -25 dBm/1KHz to Line I/F and measure Receiving level at SP_TEST1
and SP_TEST2.
5. Confirm that the level is -14 dBm ± 2 dBm and that the distortion level is < 5 %.
(vol = 3)
Procedure
42
Check or
Replace Parts
IC1, IC4, C66,
C58, C57,
C50, C52,
C53,
R52, C60,
C61
IC1, IC4, C66,
C58, C57,
C50, C52,
C53,
R52, C60,
C61
IC1, IC4, C66,
C58, C57,
C50, C52,
C53,
R52, C60,
C61
IC1, IC4, C66,
C58, C57,
C50, C52,
C53,
R52, C60,
C61
IC1, R21, R22,
R23, R24,
R25, C11,
D4, D5, C12,
C73, C74,
C75, C95, C96
IC1, R21, R22,
R23, R24,
R25, C11,
C39, C12,
C73, C74,
C75, C95, C96

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tg7120fxsKx-tga711fxsKx-tga711fxt

Table of Contents