Operation; Before Starting The Generator; Altitude Conversion Kit - Westinghouse 5300 Running Watts User Manual

Table of Contents

Advertisement

OPERATION

BEFORE STARTING THE GENERATOR

BEFORE STARTING THE GENERATOR,
REVIEW SAFETY SECTION STARTING ON
PAGE 5.
Location Selection – Before starting the generator, avoid
exhaust and location hazards by verifying:
• You have selected a location to operate the generator
that is outdoors and well ventilated.
• You have selected a location with a level and solid
surface on which to place the generator.
• You have selected a location that is at least 15 feet
(4.5 m) away from any building, other equipment or
combustible material.
• If the generator is located close to a building, make
sure it is not located near any windows, doors and/or
vents.
EXHAUST (CO)
Direct exhaust
AWAY from
windows, doors,
and vents.
Always operate the generator on a level surface.
Placing the generator on non level surfaces can
cause the generator to tip over, causing fuel and
oil to spill. Spilled fuel can ignite if it comes in
contact with an ignition source such as a very hot
surface.
NOTICE
Only operate the generator on a solid, level surface. Operating the
generator on a surface with loose material such as sand or grass
clippings can cause debris to be ingested by the generator that
could:
• Block cooling vents
• Block air intake system
14 | Westinghouse Outdoor Power Equipment, LLC
KEEP FAR AWAY
Only use OUTSIDE and
Install CO
at least 15ft away from
Detector
windows, doors, and vents
WARNING
Weather – Never operate your generator outdoors during rain,
snow or any combination of weather conditions that could
lead to moisture collecting on, in or around the generator.
Dry Surface – Always operate the generator on a dry surface
free of any moisture.
No Connected Loads – Make sure the generator has no
connected loads before starting it. To ensure there are no
connected loads, unplug any electrical extension cords that
are plugged into the control panel receptacles.
Starting the generator with loads already applied to it could result in
damage to any appliance being powered off the generator during the
brief start-up period.
Grounding the Generator – The National Electric Code
(NEC), as well as many local electrical codes, may require
the generator to be connected to earth ground. The most
common application that requires a ground rod is when you
are using the generator as a separately derived system to
provide back up power to your house. Typically this is when a
transfer switch has a switched neutral.
As the generator application has many variables that cannot
be determined by the manufacturer of the generator, a
licensed electrician will need to determine if a grounding rod is
needed.
If a licensed electrician has determine the application requires
a ground rod, make sure it is connected to earth ground by
connecting the ground terminal on the control panel to earth
ground using copper wire (minimum 10 AWG). Consult a
qualified electrician for local grounding requirements.
Neutral Bonded: There is a permanent conduct or between
the generator (stator winding) and the frame.
Be sure the generator is properly connected to earth
ground before operating. The generator must be
grounded to prevent electrical shock due to faulty
appliances.
High Altitude Operation
Engine power is reduced the higher you operate above sea
level. Output will be reduced approximately 3.5% for every
1000ft of increased altitude from sea level. This is a natural
occurrence and cannot be adjusted by engine. Increased
exhaust emissions can also result due to increased fuel
mixture. Other issues include hard starting, increased fuel
consumption and spark plug fouling. Contact our service
team 1-855-944-3571 for altitude part kits.
High Altitude Carburetor Kit Part Number: 518965
NOTICE
WARNING

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6600 peak watts

Table of Contents