Models - Graco Reactor E-20 Series Manual

Electric, heated, plural component proportioner
Hide thumbs Also See for Reactor E-20 Series:
Table of Contents

Advertisement

Models

E-20 SERIES
Full Load Peak
Part, Series
Amps*
259025, F
48
259030, F
24
259034, F
32
E-30 SERIES
Part,
Full Load Peak
Series
Amps*
259026, F
78
259031, F
34
259035, F
50
259057, F
100
259058, F
62
259059, F
35
E-XP1 SERIES
Full Load Peak
Part, Series
Amps*
259024, F
69
259029, F
24
259033, F
43
E-XP2 SERIES
Part,
Full Load Peak
Series
Amps*
259028, F
100
259032, F
35
259036, F
62
* Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and mix
chamber sizes may be less.
Total system watts, based on maximum hose length for each unit:
E-20 and E-XP1 series, 210 ft (64 m) maximum heated hose length, including whip hose.
E-30 and E-XP2 series, 310 ft (94.5 m) maximum heated hose length, including whip hose.
Maximum flow rate given for 60 Hz operation. For 50 Hz operation, maximum flow rate is 5/6 of 60 Hz maximum
flow.
312066ZAD
Voltage
System
(phase)
Watts†
230V (1)
10,200
400V (3)
10,200
230V (3)
10,200
Voltage
System
(phase)
Watts†
230V (1)
17,900
400V (3)
17,900
230V (3)
17,900
230V (1)
23,000
230V (3)
23,000
400V (3)
23,000
Voltage
System
(phase)
Watts†
230V (1)
15,800
400V (3)
15,800
230V (3)
15,800
Voltage
System
(phase)
Watts†
230V (1)
23,000
400V (3)
23,000
230V (3)
23,000
Max Flow
Primary
Rate◆
Heater
lb/min
Watts
(kg/min)
6,000
20 (9)
6,000
20 (9)
6,000
20 (9)
Max Flow
Primary
Rate◆
Heater
lb/min
Watts
(kg/min)
10,200
30 (13.5)
10,200
30 (13.5)
10,200
30 (13.5)
15,300
30 (13.5)
15,300
30 (13.5)
15,300
30 (13.5)
Primary
Max Flow
Heater
Rate◆
Watts
gpm (lpm)
10,200
1.0 (3.8)
10,200
1.0 (3.8)
10,200
1.0 (3.8)
Primary
Max Flow
Heater
Rate◆
Watts
gpm (lpm)
15,300
2.0 (7.6)
15,300
2.0 (7.6)
15,300
2.0 (7.6)
Approximate
Output per Cycle
Maximum Fluid
(A+B)
Working Pressure
gal. (liter)
psi (MPa, bar)
0.0104 (0.04)
2000 (14, 140)
0.0104 (0.04)
2000 (14, 140)
0.0104 (0.04)
2000 (14, 140)
Approximate
Output per Cycle
Maximum Fluid
(A+B)
Working Pressure
gal. (liter)
psi (MPa, bar)
0.0272 (0.1034)
2000 (14, 140)
0.0272 (0.1034)
2000 (14, 140)
0.0272 (0.1034)
2000 (14, 140)
0.0272 (0.1034)
2000 (14, 140)
0.0272 (0.1034)
2000 (14, 140)
0.0272 (0.1034)
2000 (14, 140)
Approximate
Output per Cycle
Maximum Fluid
(A+B)
Working Pressure
gal. (liter)
psi (MPa, bar)
0.0104 (0.04)
2500 (17.2, 172)
0.0104 (0.04)
2500 (17.2, 172)
0.0104 (0.04)
2500 (17.2, 172)
Approximate
Output per Cycle
Maximum Fluid
(A+B)
Working Pressure
gal. (liter)
psi (MPa, bar)
0.0203 (0.0771)
3200 (22, 220)
0.0203 (0.0771)
3200 (22, 220)
0.0203 (0.0771)
3200 (22, 220)
Models
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents