TS031A
Multi Quick Check
RJ-11/RJ-45 Tester
CUSTOMER SUPPORT INFORMATION
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018
Web site: www.blackbox.com • E-mail: info@blackbox.com

Advertisement

Table of Contents
loading

Summary of Contents for Black Box Multi Quick Check RJ-11

  • Page 1 Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: info@blackbox.com...
  • Page 3: Federal Communications Commission

    FCC AND IC RFI STATEMENTS FEDERAL COMMUNICATIONS COMMISSION INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference...
  • Page 4: Instrucciones De Seguridad

    MULTI QUICK CHECK NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT INSTRUCCIONES DE SEGURIDAD 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
  • Page 5: Nom Statement

    NOM STATEMENT 10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor. 11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato.
  • Page 6 MULTI QUICK CHECK TRADEMARKS Any trademarks mentioned in this manual are acknowledged to be the property of the trademark owners. WARNING This tester is not intended to be used on live lines. Connecting to live lines may result in damage to the tester.
  • Page 7 INTRODUCTION Introduction The Multi Quick Check tester verifies the continuity of unshielded twisted pair (UTP) cabling following EIA- 568 wiring standards (1,2; 3,6; 4,5; 7,8). It can check one, two, or three pairs of cabling as long as the same pairs are used (for example, Ethernet 10BASE-T, Token Ring, TP-PMD).
  • Page 8 MULTI QUICK CHECK Modular Jack Pin and Pair Assignments Figure 1. Handset USOC 4. Figure 2. RJ-11 USOC 4.
  • Page 9 INTRODUCTION Figure 3. RJ-12 USOC 4 and 6. Figure 4. RJ-45 USOC 8.
  • Page 10 MULTI QUICK CHECK Figure 5. RJ-45 EIA/TIA-568A. Figure 6. RJ-45 EIA/TIA-568B, AT&T ® 258A.
  • Page 11 INTRODUCTION Figure 7. RJ-45 Ethernet 10BASE-T/100BASE-T.
  • Page 12: Operation

    MULTI QUICK CHECK Operation Patch Cord Test Slide the power switch on the remote unit to the left. The red LED will blink, indicating that the power is on. Insert one end of an 8-position (RJ-45) patch cord into the master’s RJ-45 jack. Insert the other end of the patch cord into the remote’s RJ-45 jack.
  • Page 13 OPERATION Figure 8. LED sequence on the tester. Good wiring is indicated by green LEDs flashing in sequence from left to right. Faulty wiring is indicated by yellow LEDs, unlit LEDs, or out-of-sequence LED flashing.
  • Page 14 MULTI QUICK CHECK Premise Wiring Test Obtain two four-pair patch cords and verify that they are good by doing a patch cord test (see previous text). Detach the master and the remote units from each other. Turn the remote unit on and plug one end of the first patch cord into the modular jack on the tester.
  • Page 15 OPERATION Figure 9. Premise wiring test.
  • Page 16: Troubleshooting

    MULTI QUICK CHECK Battery Installation and Troubleshooting If the remote LED does not blink when the switch is pushed to the left (ON) position, the battery needs to be replaced. Remove the two screws on the bottom of the remote unit. Remove the top cover from the tester, trying to keep the slide lock, circuit board, and metal plate intact with the case bottom.
  • Page 17: Calling Black Box

    If you determine that your Multi Quick Check is malfunctioning, do not attempt to alter or repair it. Contact Black Box at 724-746-5500. The problem might be solvable over the phone. Before you do, make a record of the history of the problem.