Siemens 1FT Series Safety And Operating Instructions Manual page 25

Converter-fed low-voltage three-phase motors
Hide thumbs Also See for 1FT Series:
Table of Contents

Advertisement

Available languages

Available languages

2 Justierung des Tachoständers zum Rotorlagegeber (Rechtslauf)
Adjusting the tachogenerator stator relative to the rotor position encoder
(clockwise rotation)
0
High
Low
High
Low
High
Low
Alle Signale gegen M15 (Klemme 15 - Umrichter SIMODRIVE 6SC61.) gemessen
All signals measured at M15 (terminal 15 on SIMODRIVE 6SC61. converter)
Fig. 111.2
DEUTSCH / ENGLISH
X.311:3
Tacho Phase T
X.321:3
Tachogenerator phase T
X.331:3
X.311:8
Schranke S
X.321:8
Encoder S
X.331:8
X.311:1
X.321:1
Tacho Phase R
X.331:1
Tachogenerator phase R
X.311:9
Schranke T
X.321:9
Encoder T
X.331:9
X.311:2
X.321:2
Tacho Phase S
X.331:2
Tachogenerator phase S
X.311:7
X.321:7
Schranke R
X.331:7
Encoder R
Pg 9
(1. Achse / 1st axis)
(2. Achse / 2nd axis)
(3. Achse / 3rd axis)
(1. Achse / 1st axis)
(2. Achse / 2nd axis)
(3. Achse / 3rd axis)
(1. Achse / 1st axis)
(2. Achse / 2nd axis)
(3. Achse / 3rd axis)
(1. Achse / 1st axis)
(2. Achse / 2nd axis)
(3. Achse / 3rd axis)
(1. Achse / 1st axis)
(2. Achse / 2nd axis)
(3. Achse / 3rd axis)
(1. Achse / 1st axis)
(2. Achse / 2nd axis)
(3. Achse / 3rd axis)
19