Page 1
FI-5001 WIND TRANSDUCER Installation Manual These instructions provide the procedure for the installation of the FI-5001 Wind Transducer. For connection to the FI-501 or FI-502 wind instrument, see the FI-501/FI-502’s operator’s manual. FI-5001 WIND TRANSDUCER TERMINAL BOX (where necessary) FI-501...
Mounting procedure 1. Orient the mounting base as shown in the figure below, with the threaded part of the mounting base facing the bow. Fix the mounting base to the mast with four self-tapping screws (supplied). ± (TOP VIEW) Self-tapping Screw (4x20, 4 pcs.) (SIDE VIEW) 2.
Page 3
4. As shown in the figure below, make a loop in the cable assy. Fix the cable to the mounting base with two cable ties (local supply). Cable Assy. FI-50-SENSOR-30/50 (30 m or 50 m) Cable Tie (local supply) 5. Pass the cable assy. through the mast and connect it to the FI-501/FI-502. If the connector of the cable cannot be passed through the mast (because inside diameter of mast is too small), use the terminal box (supplied) to make the con- nection.