These instructions provide the procedure for the installation of the FI-5001 Wind
Transducer. For connection to the FI-501 or FI-502 wind instrument, see the
FI-501/FI-502's operator's manual.
TERMINAL BOX
(where necessary)
Name
Wind Transducer
Self-tapping Screw
Cable Assy.
Self-tapping Screw
Terminal Post
Cable Tie
Terminal Box Cover
Terminal Box
Installation site
Fix the transducer to the mounting mast so that its mounting base is parallel with
the water line. Also, position the transducer so its leading edge faces the bow.
FI-5001 WIND TRANSDUCER
FI-501
Type
FI-5001
4x20 SUS304
FI-50-SENSOR-30
FI-50-SENSOR-50
3x12 SUS304
4E/6
CV-100N
M03-9372
M03-9373
www.furuno.co.jp
Installation Manual
FI-5001
WIND
TRANSDUCER
OR
FI-502
12 VDC
Code No.
000-011-740
000-158-850-10
000-166-946-10
000-166-947-10
000-167-824-10
000-168-024-10
000-162-167-10
000-167-985-10
000-167-986-10
Qty
Remarks
1
4
1
Select one.
4
For Terminal Box
1
4
1
1

Advertisement

loading

Summary of Contents for Furuno FI-5001

  • Page 1 FI-5001 WIND TRANSDUCER Installation Manual These instructions provide the procedure for the installation of the FI-5001 Wind Transducer. For connection to the FI-501 or FI-502 wind instrument, see the FI-501/FI-502’s operator’s manual. FI-5001 WIND TRANSDUCER TERMINAL BOX (where necessary) FI-501...
  • Page 2: Mounting Procedure

    Mounting procedure 1. Orient the mounting base as shown in the figure below, with the threaded part of the mounting base facing the bow. Fix the mounting base to the mast with four self-tapping screws (supplied). ± (TOP VIEW) Self-tapping Screw (4x20, 4 pcs.) (SIDE VIEW) 2.
  • Page 3 4. As shown in the figure below, make a loop in the cable assy. Fix the cable to the mounting base with two cable ties (local supply). Cable Assy. FI-50-SENSOR-30/50 (30 m or 50 m) Cable Tie (local supply) 5. Pass the cable assy. through the mast and connect it to the FI-501/FI-502. If the connector of the cable cannot be passed through the mast (because inside diameter of mast is too small), use the terminal box (supplied) to make the con- nection.
  • Page 4 This page is intentionally left blank.
  • Page 6 4. 手順 3 で取り付けたケーブル組品 FI‑50‑SENSOR‑30/50 を固定具の上でルー プを作り、2 本のコンベックス(現地手配)を使って固定具上部の穴(2ヵ 所)で留めます。 5. ケーブル組品 FI‑50‑SENSOR‑30/50 を FI‑501/502 本体に接続します。ケーブ ル先端にあるコネクタがマストの内径より太く、マスト内を通らない場合 は、ケーブル組品と同梱支給の中継箱を使用します。装備・結線方法につい ては、FI‑501/502 用の取扱説明書を参照してください。 中継箱...
  • Page 7 装備手順 1. 付属のタッピンネジ(4x20、4 本)を使って、マストの上に固定具を取り付 けます。 このとき、下図のように固定具のネジ部が船首方向になるようにしてください。 2. マストに取り付けた固定具に、センサーに付いているコネクタを通してから ネジ部を手で回して固定します。 3. センサーのコネクタに、ケーブル組品 FI‑50‑SENSOR‑30/50(30m または 50m) を確実に差し込みます。...
  • Page 8 風向風速センサー FI-5001 装備要領書 本要領書では、オプションの風向風速センサー FI-5001 の取付け方法について記載 しています。表示部本体との接続については、FI-501/502 用の取扱説明書を参照し てください。 構成 名称 型式 コード番号 数量 備考 風向風速セ ンサー FI-5001 000-011-740 タ ッ ピ ン ネジ 4x20 SUS304 000-158-850-10 ケーブル組品 FI-50-SENSOR-30 000-166-946-10 いずれか を選択 FI-50-SENSOR-50 000-166-947-10 タ ッ ピ ン ネジ 3x12 SUS304 000-167-824-10 中継箱用...