MODEL QTREN080C
VENTILATION FAN
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
3. Installation work and electrical wiring must be done by a
qualifi ed person(s) in accordance with all applicable codes
and standards, including fi re-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the fl ue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating
equipment manufacturer's guideline and safety standards such
as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
8. This unit must be grounded.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further
information and requirements.
Installer: Leave this manual with the homeowner.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive
appearance - lower or remove grille and vacuum interior of unit
with the dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the motor with the exact service motor. The impeller should also
be replaced.
OPERATION
Use an on/off switch or speed control to operate this ventilator.
See "Connect Wiring" for details.
WARRANTY
NUTONE THREE-YEAR LIMITED WARRANTY
NuTone warrants to the original consumer purchaser of its products that
such products will be free from defects in materials or workmanship for
a period of three years from the date of original purchase. THERE ARE
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
During this three-year period, NuTone will, at its option, repair or replace,
without charge, any product or part which is found to be defective under
normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP
STARTERS AND TUBES. This warranty does not cover (a) normal
maintenance and service or (b) any products or parts which have been
subject to misuse, negligence, accident, improper maintenance or
repair (other than by NuTone), faulty installation or installation contrary to
recommended installation instructions.
The duration of an implied warranty is limited to the three-year period
as specifi ed for the express warranty. Some jurisdictions do not allow
limitation on how long an implied warranty lasts, so the above limitation
may not apply to you.
NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE'S
OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE
REMEDY UNDER THIS WARRANTY. NUTONE SHALL NOT BE
LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES
ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR
PERFORMANCE. Some jurisdictions do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation
may not apply to you.
This warranty gives you specifi c legal rights, and you may also have other
rights, which vary from province to province. This warranty supersedes all
prior warranties.
To qualify for warranty service, you must (a) notify NuTone at the address
or telephone number stated below, (b) give the model number and part
identifi cation and (c) describe the nature of any defect in the product or
part. At the time of requesting warranty service, you must present evidence
of the original purchase date.
Broan-NuTone Canada, 1140 Tristar Drive, Mississauga, Ontario L5T 1H9
(1-888-882-7626)
MODEL QTREN080C
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for NuTone QTREN080C

  • Page 1 To qualify for warranty service, you must (a) notify NuTone at the address or telephone number stated below, (b) give the model number and part identifi cation and (c) describe the nature of any defect in the product or part.
  • Page 2: Typical Installations

    MODEL QTREN080C Page 2 TYPICAL INSTALLATIONS Housing mounted Housing anywhere mounted to between trusses I-joists. using hanger bars. PLAN THE INSTALLATION Housing mounted anywhere between Do not install above or inside this area. I-joists using hanger bars. Housing Cooking mounted to Equipment joists.
  • Page 3 MODEL QTREN080C Page 3 INSTALL HOUSING & DUCT 1a. Mount SCREW (2) HOLE FOR OPTIONAL housing to SCREW MOUNTING (4) joist or I-joist. Use a pliers to bend housing TABS out to 90 . Hold housing in place so that...
  • Page 4: Connect Wiring

    97016468 Motor Plate 99250959 Washer #8 (4 req’d) 99260558 Nut, Hex Lock #8-32 (4 req’d) 97016589 Blower Assembly (QTREN080C) (includes key nos. 6 thru 11) 97016915 Grille Assembly - Microban (includes key no. 13) 99140199 Grille Spring (2 req’d) 99111293...
  • Page 5: Utilisation Et Entretien

    2. Afin d’éviter tout dommage au roulement du moteur et Pour le service sous garantie, vous devez (a) aviser NuTone à l’adresse ou de débalancer ou de rendre bruyante la roue du moteur, au numéro de téléphone ci-dessous, (b) donner le numéro du modèle et gardez l’appareil à...
  • Page 6: Planification De L'installation

    MODÈLE QTREN080C Page 6 MONTAGES TYPES Boîtier monté CÂBLE ÉLECTRIQUE n’importe où BARRES DE SUSPENSION (s’étend jusqu’à 24 po) Boîtier monté sur entre des poutres ENTRETROISE POUR SOLIVE EN I des solives en I. triangulées BOÎTIER PATTES utilisant des DE MONTAGE barres de CÂBLE...
  • Page 7 MODÈLE QTREN080C Page 7 INSTALLATION DU BOÎTIER ET DU CONDUIT 1a. Installation TROU POUR VIS DE VIS (2) du boîtier à la MONTAGE OPTIONNELLE (4) solive ou à la solive en I Utiliser des pinces pour plier les PATTES du boîtier PATTES à...
  • Page 8: Branchement Électrique

    Plaque de moteur 99250959 Rondelle n 8 (4 requises) 99260558 Écrou de blocage hexagonal 8-32 (4 requis) 97016589 Bloc ventilateur (QTREN080C) (inclut les repères n 6 à 11) 97016915 Ensemble grille - Microban PATTE (inclut le repère n 99140199 Ressort de la grille (2 requis)