QTREN SERIES
QUIET VENTILATION FAN
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer at the address or telephone
number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment manufacturer's guideline
and safety standards, and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to a GFCI
(Ground Fault Circuit Interrupter) - protected branch circuit (ceiling
installation only).
8. This unit must be grounded.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced blower
wheels, keep drywall spray, construction dust, etc. off power unit.
3. Please read specification label on product for further information
and requirements.
OPERATION
Use an on/off switch or speed control to operate this ventilator. See
"Connect Wiring" for details.
INSTALLER: Leave this manual with the homeowner • HOMEOWNER: Cleaning and Maintenance on page 3
MODELS QTREN090C • QTREN110C
TYPICAL INSTALLATIONS
POWER
CABLE
CEILING
MATERIAL
Housing mounted to I-joists.
Use I-joist spacer block (provided).
POWER CABLE
CEILING
MATERIAL
Housing mounted to joists.
POWER CABLE
CEILING
MATERIAL
Housing mounted to truss.
Page 1
I
"
" JOIST
SPACER BLOCK
MOUNTING
TABS
HOUSING
I
"
"
GRILLE
JOIST
MOUNTING TABS
CEILING
JOIST
HOUSING
GRILLE
MOUNTING
TABS
TRUSS
HOUSING
GRILLE

Advertisement

Table of Contents
loading

Summary of Contents for NuTone QTREN Series

  • Page 1 MODELS QTREN090C • QTREN110C Page 1 QTREN SERIES QUIET VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING TYPICAL INSTALLATIONS TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: " " JOIST 1. Use this unit only in the manner intended by the manufacturer. If you...
  • Page 2: Plan The Installation

    MODELS QTREN090C • QTREN110C Page 2 PLAN THE INSTALLATION INSTALL HOUSING & DUCT 1. Bend housing tabs. ROOF CAP Use pliers to bend housing TABS out to 90 4-IN. (101.6 mm) TABS ROUND DUCT 2. Mount SPACER housing to (use for mounting to -Joist) joist.
  • Page 3: Connect Wiring

    MODELS QTREN090C • QTREN110C Page 3 CONNECT WIRING INSTALL GRILLE 6. Finish ceiling. Install ceiling material. Cut out around housing. 7. Attach grille to housing. Squeeze grille springs and insert them into slots on each side of housing. 8. Push grille against ceiling.
  • Page 4: Service Parts

    TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this three-year period, Broan-NuTone Canada will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
  • Page 5 MODÈLES QTREN090C • QTREN110C Page 1 VENTILATEUR SILENCIEUX SÉRIE QTREN LIRE ET CONSERVER CES INSTRUCTIONS AVERTISSEMENT INSTALLATIONS TYPES POUR RÉDUIRE LE RISQUE D’INCENDIE, D’ÉLECTROCUTION OU DE BLESSURES, OBSERVER LES RÈGLES SUIVANTES : 1. N’utiliser cet appareil que de la manière prévue par le fabricant. Pour ESPACEUR DE CÂBLE toute question, contacter le fabricant à...
  • Page 6: Planification De L'installation

    MODÈLES QTREN090C • QTREN110C Page 2 PLANIFICATION DE INSTALLATION DU BOÎTIER ET L’INSTALLATION DU CONDUIT 1. Plier les ÉVENT DE TOITURE languettes du boîtier. Uliliser des pinces pour plier les LANGUETTES du CONDUIT ROND boîtier à un angle 4 po (101,6 mm) LANGUETTES de 90 2.
  • Page 7: Connexion Électrique

    MODÈLES QTREN090C • QTREN110C Page 3 CONNEXION ÉLECTRIQUE FIXATION DE LA GRILLE 6. Finir le plafond. Poser le matériau du plafond. Couper le matériau autour du NOIR NOIR boîtier. INTERRUPTEUR 7. Fixer la grille BLANC MARCHE / ARRÊT au boîtier. Comprimer les NOIR ressorts de la grille...
  • Page 8: Pièces De Rechange

    SE LIMITER AUX GARANTIES IMPLICITES POUR FIN DE COMMERCIALISATION ET DE CONVENANCE DANS UN BUT PARTICULIER. Pendant cette période de trois ans, Broan-NuTone Canada, à son choix, réparera ou remplacera, gratuitement, tout produit ou pièce qui s’avère défectueux dans des conditions normales d’utilisation et d’entretien.