READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a
12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specification label on product for further informa-
tion and requirements.
Installer: Leave this manual with the homeowner.
MODELS QTRN050F • QTREN080 • QTREN110
FANS
TM
To register this
product visit:
www.nutone.com
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appear-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the blower assembly (includes motor and impeller).
OPERATION
Use an on/off switch or speed control to operate this ventilator. See
"Connect Wiring" for details. Use of speed controls other than the
NuTone Models 78V and 78W may cause a motor humming noise.
WARRANTY
BROAN-NUTONE THREE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products
that such products will be free from defects in materials or workmanship
for a period of three years from the date of original purchase. THERE ARE
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
During this three-year period, Broan-NuTone will, at its option, repair or
replace, without charge, any product or part which is found to be defective
under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP
STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES,
FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSO-
RIES FOR DUCTING. This warranty does not cover (a) normal maintenance
and service or (b) any products or parts which have been subject to mis-
use, negligence, accident, improper maintenance or repair (other than by
Broan-NuTone), faulty installation or installation contrary to recommended
installation instructions.
The duration of an implied warranty is limited to the three-year period as
specified for the express warranty. Some states do not allow limitation on how
long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-
NUTONE'S OPTION, SHALL BE THE PURCHASER'S SOLE AND EX-
CLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL
NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL
DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT
USE OR PERFORMANCE. Some states do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation
may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. This warranty supersedes all prior
warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the
address or telephone number stated below, (b) give the model number and
part identification and (c) describe the nature of any defect in the product or
part. At the time of requesting warranty service, you must present evidence
of the original purchase date.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027
www.nutone.com
888-336-3948
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for NuTone ULTRA SILENT QTRN Series

  • Page 1 To qualify for warranty service, you must (a) notify Broan-NuTone at the 4. Please read specification label on product for further informa- address or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or tion and requirements.
  • Page 2: Typical Installations

    MODELS QTRN050F • QTREN080 • QTREN110 Page 2 TYPICAL INSTALLATIONS Housing mount- Housing mount- ed anywhere ed to I-joists. between trusses using hanger bars. PLAN THE INSTALLATION Housing mount- ed anywhere COOKING AREA between Do not install above or inside this area. I-joists using hanger bars.
  • Page 3 MODELS QTRN050F • QTREN080 • QTREN110 Page 3 INSTALL HOUSING & DUCT 1a. Mount SCREW (2) HOLE FOR OPTIONAL housing to SCREW MOUNTING (4) joist or I-joist. Use a pliers to bend housing TABS out to 90 . Hold housing in place so that TABS the housing tabs...
  • Page 4: Connect Wiring

    Spacer (2 supplied) be ordered on our web- QTNHB1 Hanger Bar Kit site. Please visit us at www.nutone.com (QTREN080, QTREN110) 99420665 Thumbscrew, #8-18 x .375 Order service parts by “Part No.” - not by “Key No.” SERVICE NOTE To remove Blower Assembly: Unplug motor.
  • Page 5: Limpieza Y Mantenimiento

    PROPÓSITO PARTICULAR. de Calefacción, Refrigeración y Aire Acondicionado (American Durante este período de tres años, Broan-NuTone, a su criterio, reparará o reem- plazará, sin cargo alguno, cualquier pieza o producto que se encuentre defectuoso Society for Heating, Refrigeration and Air Conditioning Engi- bajo condiciones normales de uso y servicio.
  • Page 6: Instalaciones Típicas

    MODELOS QTRN050F • QTREN080 • QTREN110 Página 6 INSTALACIONES TÍPICAS Montaje de la cubierta en Montaje de la cualquier parte cubierta en vigu- entre armaduras etas “I” . por medio de barras de sus- pensión. PLANIFICACIÓN DE LA Montaje de la cu- bierta en cualqui- INSTALACIÓN er parte entre las...
  • Page 7 MODELOS QTRN050F • QTREN080 • QTREN110 Página 7 INSTALE LA CUBIERTA Y EL CONDUCTO 1a. Instale la ORIFICIO PARA MONTAJE TORNILLO (2) cubierta en CON TORNILLO OPCIONAL (4) las viguetas o viguetas “I” . Con un alicate, doble las LENGÜETAS de la cubierta a 90°.
  • Page 8: Conexión Eléctrica

    Tornillo de mariposa n. 8-18 x 0.375 Visítenos por favor en www.nutone.com Al hacer el pedido de una pieza de servicio se debe especificar el número de la pieza (no el número de la clave). NOTA DE SERVICIO Para desmontar el conjunto del ven- tilador: Desenchufe el motor.