Download Print this page
Yamaha HY144-D Firmware Update Manual

Yamaha HY144-D Firmware Update Manual

Hide thumbs Also See for HY144-D:

Advertisement

Quick Links

HY144-D Firmware Update Guide
Thank you for choosing a Yamaha product.
This guide explains how to update the built-in Dante module firmware (Dante firmware) integrated in
the HY144-D.
■ Precautions (Please be sure to read this section first!)
・ The user assumes full responsibility for the update.
・ Update the firmware components one unit at a time.
・ Please note that the device may be damaged if you fail to follow these instructions properly, or
turn off the device or disconnect the cable while the update is in progress.
・ If the update fails, and the device still does not operate correctly even after you execute the update
once again, please contact your Yamaha dealer.
・ Yamaha Corporation owns exclusive copyrights for this update guide.
・ Audinate owns exclusive copyrights for the Dante firmware and its update program.
・ It is prohibited to duplicate or modify the firmware, software or guides, in part or in their entirety,
without permission from the copyright owner.
・ The screen shots in this guide are for use with this update procedure only and may be different
from the actual screen shots.
・ Dante is a registered trademark of Audinate.
・ Windows is a registered trademark of Microsoft ® Corporation in the United States and other
countries.
・ Mac and macOS are trademarks of Apple Inc., registered in the U.S. and other countries.
・ The company names and product names in this document are the trademarks or registered
trademarks of their respective companies.
1

Advertisement

loading

Summary of Contents for Yamaha HY144-D

  • Page 1 ・ If the update fails, and the device still does not operate correctly even after you execute the update once again, please contact your Yamaha dealer. ・ Yamaha Corporation owns exclusive copyrights for this update guide. ・ Audinate owns exclusive copyrights for the Dante firmware and its update program.
  • Page 2 ■ Checking the version number ・ You may check the Dante firmware version number from the FIRMWARE VERSION screen of CS-R10/CS-R10-S/CSD-R7, RIVAGE PM Editor or Dante Firmware Update Manager of Audinate. PM10 (FIRMWARE VERSION screen of the MAINTENANCE) Dante Controller (Device View)
  • Page 3 ■ Update procedure sequence Update each firmware component in the following sequence. To update more than one HY144-D, configure “Computer TCP/IP setting (for Dante)” and perform “Dante firmware update” one by one. Install the Dante Firmware Update Manager Computer TCP/IP setting (for Dante) Updating the Dante firmware ・For details of the Dante Firmware Update Manager, refer to “AUD-MAN-Firmware Update Manager"...
  • Page 4 ■ Install the Dante Firmware Update Manager Before you update the Dante firmware, you must install the Dante Firmware Update Manager. Double-click the Dante Firmware Update Manager installer downloaded in “Preparing for the update” (Windows: DanteFirmwareUpdateManager-x.x.x.exe, Mac: DanteFirmwareUpdateManager-x.x.x.dmg) and follow the on-screen instructions to install the firmware.
  • Page 5 ■ Computer TCP/IP setting (for Dante) To update Dante firmware, configure computer TCP/IP settings. Windows Open the Network and Sharing Center as described below. Windows 7 Select [Start] → [Control Panel], then click or double-click [Network and Sharing Center] or [View network status and tasks].
  • Page 6 Click [System Preferences] → [Network]. The “Network” dialog box will be displayed. Click the service that you want to connect to the device. If you're using the Ethernet port that's built into the Mac, click [Ethernet]. In “Configure IPv4,” choose [Using DHCP]. Click [Apply] button, then close “Network”...
  • Page 7 Described below are the procedures to update the Dante module firmware integrated in the HY144-D. ・Perform the update with the HY144-D installed to the DSP-R10 HY card slot 3/4, to the CSD-R7 HY card slot 2/3 or to the RPio622/RPio222.
  • Page 8 When [Override Device Matching] is not checked, only devices supported in the update file are displayed. For this reason, updating with wrong files is prevented. However, it is necessary to check the [Override Device Matching] only when you update the HY144-D Dante firmware from V3.8.1.4 or earlier to V3.10.4.1 or later.
  • Page 9 Check the version of the update files and the version number indicated in the HY144-D line. ・If the HY144-D is not indicated, click [Refresh]. If it is still not indicated, use Dante Controller to check whether the cable might be disconnected or broken, whether the TCP/IP settings are correct or not, and whether the device which is installed the HY144-D is running or not.
  • Page 10 To restore the Dante module from failsafe mode, a recovery image must be sent from the Firmware Update Manager. If the red ERROR indicator of the HY144-D is lit, it may be that the Dante module is in failsafe mode. Use Dante Controller to check whether the Dante module is in failsafe mode.
  • Page 11 Turn off the power to the device to which the HY144-D is installed. 2. Separate the HY144-D from the Dante network. 3. Connect the Dante [PRIMARY] connector of the HY144-D to the Ethernet connector on the computer using an Ethernet cable.
  • Page 12 When the HY144-D is detected, click the [Stop Scan] button. If several minutes have passed without detection, use Dante Controller to check whether the cable might be disconnected or broken, whether the TCP/IP settings are correct or not, and whether the device which is installed the HY144-D is running or not.
  • Page 13 HY144-D is installed. After recovery, restart the Dante module. If you power-off the device to which the HY144-D is installed before restart is completed, the data of the Dante module will be corrupted, and you will have to perform the recovery once again.