Outlets; Start Dial (Off/Run/Choke); Usb Port; Eco Mode - Craftsman CMXGIAC2200 Instruction Manual

Inverter generator
Table of Contents

Advertisement

Available languages

Available languages

Outlets

120 VAC, Duplex Outlet
See
Fig.
C. The 120 Volt outlet is overload protected by
the 15 Amp push button circuit protector. Each outlet
will power 120 Volt AC, single phase, 60 Hz electrical
loads requiring up to 1700 watts (1.7 kW).
Fig. C

Start Dial (Off/Run/Choke)

This controls the ON/OFF functions, choke and fuel valve
operation
(Fig.
D).
• The OFF position
1
flow.
• The RUN position
gradually reduce the use of the choke.
• The CHOKE position
start the engine.
NOTE: The CHOKE is not required to start a warm engine.
Fig. D
1

USB Port

The 5 VDC, 1.5 Amp USB outlet allows charging of com-
patible electronic devices.

Eco Mode

The economy switch has 2 modes of operation:
• On: The quietest mode and best when running appli-
ances or equipment that are resistive loads (non-motor
starting), (example: TV, video game, light, radio).
• Off: Best when running a both inductive (motor-start-
ing loads) and resistive (non-motor starting loads),
especially when these loads are turning on and off
(example: RV, air conditioner, hairdryer).
6
stops the engine and shuts off fuel
is for normal operation and to
2
switches the fuel valve on to
3

Generator Status Lights

See
Fig.
E.
• Overload LED (orange): Indicates system overload
. During motor starting it is normal for the overload
2
LED to illuminate for a few seconds. If LED stays illumi-
nated and the ready LED turns off, the engine will con-
tinue to run without output power. Remove all applied
loads and determine if attached devices exceed recom-
mended output power. Check for faulty or shorted con-
nections. To restore electrical output, turn dial OFF to
reset. Start engine. If condition was corrected, the
orange LED will not illuminate and electrical output will
be restored. Loads can be applied once the green LED
illuminates. If the orange LED returns, contact an IASD.
• Low Oil Level LED (red): Illuminates when oil level is
below safe operating level. Engine shuts down
• Power LED (green): Indicates output from generator
(unless there is a low oil or overload condition).
3
Fig. E
000424
1

Circuit Protectors

The AC outlets are protected by an AC circuit protector.
The DC outlets are protected by a DC circuit protector. If
2
the generator is overloaded or an external short circuit
occurs, the circuit protector will trip. If this occurs, dis-
connect all electrical loads to determine the cause of the
problem before using the generator again. Reduce the
load if the circuit protector is tripped.
NOTE:
Continuous
3
cause damage to generator or equipment.
Push the button of the protector to reset the circuit pro-
002347
tector.
2
tripping of the circuit protector may
Owner's Manual for Portable Generator
.
1
002335
3