Diagnostics (Machine Status Display); General; Msd Message Display; Message Classification - Bosch Rexroth IndraMotion MTX micro Commissioning Manual

Easy setup for standard turning and milling machines
Hide thumbs Also See for Rexroth IndraMotion MTX micro:
Table of Contents

Advertisement

70/141
Bosch Rexroth AG
PLC Startup
6.4

Diagnostics (Machine Status Display)

6.4.1

General

6.4.2

MSD Message Display

6.4.3

Message Classification

Rexroth IndraMotion MTX micro Easy setup for Standard Turning and Milling Machines
Errors, warnings and messages displayed in plaintext during ongoing operation
help to reduce standstill and startup times. The machine status display (MSD)
allows generation of a total of 2048 messages from the PLC program. The NC
user interface signals the corresponding diagnostics to the user in plaintext.
Each diagnostics message is controlled by a separate message bit in the PLC
program. The MTX micro-c saves the displayed MSD diagnostics messages in
a logbook in the CNC. A diagnostics message can be displayed as
an error (red),
a warning (yellow), or
a note (green) on the user interface.
Currently existing messages are displayed in the diagnostics bar on the HMI
screen (1). This bar is visible on all screens. If active at the same time, several
messages are displayed alternately in the diagnostics bar.
The "Diagnosis" operating area displays all active messages and more detailed
diagnostics texts relating to these messages.
1:
Diagnostic bar in the header
2:
List of active diagnostics messages
3:
Text describing the cause of the message selected under 2
4:
Text describing a remedy for the message selected under 2
Fig.6-11:
Diagnostics message display on the HMI
If a specific machine status occurs, there should also be a specific reaction.
The MTX micro-c features such an option of classifying the MSD messages.
DOK-MTXMIC-EASY*******-CO04-EN-P

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents