X7E1 And X7E2: Plug-In Connector Assignment For Ethernet Interface (Coding D), M12, 4-Pin, Socket; Led Status Indicators - Bosch rexroth HS5E Instruction Manual

For axial piston variable pump a4vso, a4vbo, a4vsg and a4csg
Table of Contents

Advertisement

LED
Interface
1
X7E1
2
Electronics-
3
module
4
Module status
X7E2
5
6
Table 18: Indicators of status LED
Module status
Indicator status
LED (LED 4)
Off
no voltage supply
Green/red flashing
Self-test
Green flashing
Drive ready for
operation
Green
in control
Red flashing
Warning
Red
Installation | A4... with HS5E(V)(L) control system Series 1x and 30
7.6.5 X7E1 and X7E2: Plug-in connector assignment for Ethernet interface
(coding D), M12, 4-pin, socket
Table 17: Pin assignment of X7E1 and X7E2:
Pin
Assignment
1
TxD +
2
RxD +
3
TxD -
4
RxD -
5
not assigned
Use a shielded bus cable as the data cable. When doing this, the shield should be
connected to the connector housing.

7.6.6 LED status indicators

Sercos
EtherNET/IP
Activity
Activity
Link
Link
S
Network status
Module status
Activity
Activity
Link
Link
Network status
LED
Off
Green
Fault
LEDs 1, 2, 5, and 6 refer to interfaces "X7E1" and "X7E2"
- Link: Cable is plugged in, connection has been established (lit up permanently)
- Activity: Data has been sent/received (flashing)
Module status LEDs 3 and 4 refer to the electronics module
For a detailed description of the diagnosis LEDs, refer to the functional
description of the Rexroth HydraulicDrive.
EtherCAT
PROFINET
not used
Activity
Link/Activity
Link
Network status
Network status
Module status
Module status
not used
Activity
Link/Activity
Link
Indicator status
no voltage supply
Operation
RE 92076-01-B/2021-04-22, Bosch Rexroth AG