ENGLISH
The hob is supplied with a three pole terminal
block designed for a 230 V connection. The
yellow/green earth wire must always be con-
nected to the terminal marked with the symbol
.
Upon completion, secure the connection cable
with the cable clamp and close the terminal
block.
Gas setting conversion
This model is designed for use with natu-
ral gas but can be converted for use with
butane or propane gas providing the correct
injectors. The injectors not supplied with the
appliance have to be ordered from After Sales
Service (refer to the Service chapter).
For data concerning injector replacement, see
chapter "Technical data"
Warning! Conversion or replacement
can only be performed by a registered
installer.
To replace injectors:
1. Remove pan support.
2. Remove burner cap and crown.
3. With a socket spanner 7 unscrew and re-
move the injectors, replace them with the
ones required for the type of gas in use.
4. Reassemble the parts, following the same
procedure backwards.
Important! Replace the rating label (placed
near gas supply pipe) with relevant one for the
new type of gas supply before sealing the
appliance. If the appliance is already sealed
please stick it directly on the user manual
booklet after Technical data chapter close to
the rating plate drawing.
You can find this label in package sup-
plied with appliance
If the feeding gas pressure will be differ-
ent or variable, comparing with the re-
quired, you must install an appropriate pres-
sure adjuster, which is not supplied with the
product and if needed must be ordered sep-
arately from the local After Sales Service (refer
to the Service chapter). The pressure adjuster
must be fitted on gas supply pipe, in compli-
ance with the rules of the force.
The rating plate is located on the lower casing
of the hob.
Adjusting flame level
When hob has been fully installed, it is neces-
sary to check the minimum flame setting:
1. Turn the gas tap to the maximum position
and ignite.
2. Set the gas tap to the minimum flame po-
sition then turn the control knob from mini-
mum to maximum several times. If the flame
is unstable or extinguished, follow the pro-
cedure further.
3. Re-ignite the burner and set to minimum.
4. Remove the control knob.