■[F10] Accumulated value hold
The default setting is to clear the accumulated flow value when the power supply is turned off.
This function enables the accumulated flow value to be stored in permanent memory every 2 or 5 minutes.
The maximum writable limit of the memory device is 1 million cycles, which should be taken into
consideration.
For example, if the product is operated 24 hours per day, the life will be as follows:
Data stored every 5 minutes: 5 minutes x 1 million cycles = 5 million minutes = 9.5 years
Data stored every 2 minutes: 2 minutes x 1 million cycles = 2 million minutes = 3.8 years
<Operation>
Press the
or
Select Accumulated value hold
[EEP] and the set value are displayed in turn.
Press the
or
: When accumulated flow external reset is repeatedly input, wait for a time longer than the time required to store the value.
button in function selection mode to display [F10].
Press the
button.
button to select.
Press the
button.
[F10] Selection of Accumulated value hold completed
Return to function selection mode.
-38-
No.PF※※-OMJ0018-F