REMOVAL/REPLACEMENT INFORMATION

5.2 Replacement Procedures

To replace the Storage/Control I/O Module:
1. Make certain you are properly ESD grounded. Use a wrist strap, attached to the
ground connector located in the front, inside of the VCO. The ground connector can be
identified by the label: CONNECT ESD WRIST STRAP HERE
2. Place the replacement Storage/Control I/O Module on the antistatic mat or envelope.
3. Verify that the Combined Controller that is to be connected to the Storage/Control I/O
Module is not plugged into the backplane.
4. Verify that all the jumpers on the replacement card correspond with those on the
removed Storage/Control I/O Module.
Verify that the jumper configuration is appropriate for the system configuration.
Refer to Serial Ports 1 through 4 and Jumper Settings for details on jumper settings
for the Storage/Control I/O Module.
5. Grasp the replacement card by the sides of the front panel and align it with the top and
bottom card guides of the subrack.
6. Push the card inward until it makes contact with the midplane.
7. Firmly push the card toward the midplane. The card fits tightly into the midplane
connectors and some force is required to seat the card back firmly into the midplane
connectors.
8. Use a 1/8-inch bladed screwdriver to tighten the mounting screws at the top and
bottom of each card into the tapped holes on the mounting rail.
9. Plug the Combined Controller into the backplane.
10. If installing in a nonredundant system, make sure the system is powered on.
11. If the hard disk drive does not contain the Generic software, install the software. Refer
to the system release notes for instructions on installing the Generic software, backing
up and restoring the database, and licensing.