Mounting
3.2

Installation

3.2.1
Panel PC 670
Mounting location
and dimensions
*)
112 ± 0.5
Drill hole for
screw fixings
M6/ 7
Gasket area
Operating units
(a) with key-based front panels:
10.4" TFT / 12.1" TFT
15.1" TFT
(b) with touchscreen front panels:
12.1" TFT
15.1" TFT
Fig. 3-3
Dimensions for installation of the operating unit of Panel PC 670
3-4
The operating unit can be fitted in the mounting cut-out with either clamps
or screws. Screwed joints are not possible with the 12.1" touchscreen
version!
Protection class IP 65 is possible when the operating unit is secured with
clamps (in conjunction with a continuous gasket).
Protection class IP 54 is achieved with screw fixings.
The permissible mounting locations will depend on the attached computing
unit.
± 1
± 1
L3
L3
± 1
± 1
S1
S2
L1
+1
± 1
± 1
S1
S1
± 0.2
L4
L1 L2 L3 L4 L5 A1 A2 S1 S2
450 290 78 465 235 16 10
450 321 51 465 279 16 17
368 290 —
450 290 81 465 235 16 10
SIMATIC Panel PC 670 / 870 Operating Unit, Equipment Manual
±1
A1
*)
112 ± 0.5
Pressure points
for clamps
cut-outs only for 15" TFT
*)
(keyboard version),
— 16 10 35 19
(for dimensions,
see Fig. 3-1)
min. 1.5 – max. 6
Edition 07/02