Top feed stroke movement
.04.08
Rule
When, approaching from above, the needle bar's lower edge is located 33 mm above the
needle plate's upper edge, the top transporter should not move when the slotted lever 3
moves up and down.
Fig. 13 - 08
O Loosen the screws 1 until the eccentric 2 is difficult to turn on its shaft.
O Move the needle bar into the appropriate position.
O Turn the eccentric 2 according to the rule.
O Tighten the screws 1.
2
1
33 mm
Adjustment
3
13