About Rack Mounting

Attaching the included rack-mount angle brackets lets you install the V-600UHD in a 19-inch rack.
Attaching the rack-mount angles
1.
Turn off the power to the V-600UHD and disconnect
the power cord and all connection cables.
2.
Remove the mounting screws (6) specified in the
figure.
3.
Using the mounting screws (6) you removed in step
2, attach the rack-mount angles.
* Both of the rack-mount angles have the same shape; there is no
difference between left and right.
NOTE
When uninstalling the rack-mount angles
5 Before uninstalling the rack-mount angles, turn off the power to
the V-600UHD and disconnect the power cord and all connector
cables.
5 Be sure to block the screw holes with the removed screws. Using
different screws can result in malfunction.
Important notes on rack mounting
5 Before mounting, turn off the power to the V-600UHD and detach
the power cord and all connection cables.
5 When mounting the unit, take care not to pinch your fingers etc.
5 The video fader protrudes beyond the mounting surface of the
rack. Take care not to damage it when mounting the unit.
5 To prevent incorrect operation or malfunction, take care not to
subject areas protruding beyond the rack to accidental impact.
5 To ensure room for connectors and cables, leave 2U of clearance
above the unit.
5 Use all threaded holes (at 3 locations on each side, for a total of
6) to secure the unit to the rack using screws. Screws for rack-
mounting are not included.
5 Never transport the rack with the unit installed in it. The impact of
shaking or vibration might deform the rack-mount angles.
5 When mounting the V-600UHD in a rack, pay attention to the
following points to ensure efficient cooling.
– Install in a well-ventilated location.
– Avoid blocking the cooling-fan intake and exhaust ports on the
side panels of the V-600UHD.
– Avoid mounting the unit in a sealed-type rack. Warm air within
the rack cannot escape and is sucked into the unit, making
efficient cooling impossible.
– If the back of the rack cannot be opened, install an exhaust
port or ventilation fan at the top back surface of the rack where
warm air collects.
5 Also read the "Placement" (p. 3) under "IMPORTANT NOTES. "
9