Roland V-40HD Manual

Roland V-40HD Manual

Multi-format video switcher
Hide thumbs Also See for V-40HD:

Advertisement

Quick Links

Remote Control Guide
The V-40HD supports remote control via MIDI and RS-232C. This document describes settings for
remote control
Copyright © 2012 ROLAND CORPORATION
All rights reserved. No part of this publication may be reproduced in any form without the written
permission of ROLAND CORPORATION.
* Roland is either registered trademark or trademark of Roland Corporation in the United States and/or other countries.
* All product names mentioned in this document are trademarks or registered trademarks of their respective owners.
1PS

Advertisement

Table of Contents
loading

Summary of Contents for Roland V-40HD

  • Page 1 All rights reserved. No part of this publication may be reproduced in any form without the written permission of ROLAND CORPORATION. * Roland is either registered trademark or trademark of Roland Corporation in the United States and/or other countries. * All product names mentioned in this document are trademarks or registered trademarks of their respective owners.
  • Page 2: Table Of Contents

    Contents Remote Controlling via MIDI ................3 MIDI Control Modes of the V-40HD ..............................3 MIDI Menu of the V-40HD ..................................4 MIDI Implementation ...................5 Messages Transmitted and Received in Standard MIDI Mode....................5 Messages Transmitted in V-LINK Master Mode ..........................8 Messages Received in V-LINK Slave Mode ...........................9 Messages Received in MVC Mode ..............................
  • Page 3: Remote Controlling Via Midi

    These are the MIDI control modes for the V-40HD. Select one mode best suited for your connected device or your application. Standard MIDI mode This is the mode for remote controlling the V-40HD from an external MIDI device (like a keyboard) or linking 2 units of the V-40HD. V-LINK Master mode This is the mode for remote controlling an external V-LINK device from the V-40HD.
  • Page 4: Midi Menu Of The V-40Hd

    When you use in V-LINK master mode, select [V-LINK Master] in [Status]. The MIDI device ID of the V-40HD will be [10H]. Using in V-LINK Slave mode When you use in V-LINK slave mode, send V-LINK ON message while the V-40HD is in standard MIDI mode. The MIDI device ID of the V-40HD will be [10H].
  • Page 5: Midi Implementation

    MIDI Implementation Messages Transmitted and Received in Standard MIDI Mode Control Change Source Select Status 2nd Byte 3rd Byte n = MIDI Channel Number k = Source : 00H-03H(HDMI, RGB/Component, Composite, Shared Input) PVW Select Status 2nd Byte 3rd Byte n = MIDI Channel Number k = Output Select : 00H-03H(INPUT, PST, PGM, DSK) A-BUS/PGM Cross-point Select...
  • Page 6 MIDI Implementation Picture in Picture Select Status 2nd Byte 3rd Byte n = MIDI Channel Number k = PinP Button 0H - 4H (Off, PinP1 - PinP4) WIPE PATTERN AUTO Button Status 2nd Byte 3rd Byte n = MIDI Channel Number DSK AUTO Button Status 2nd Byte...
  • Page 7 MIDI Implementation HDMI Audio Delay Status 2nd Byte 3rd Byte n=MIDI Channel Number kk=Time : 00H-78H(0.0flame - 12.0flame) Audio In Delay Status 2nd Byte 3rd Byte n=MIDI Channel Number kk= Time : 00H-78H(0.0flame - 12.0flame) Video Fader Status 2nd Byte 3rd Byte n=MIDI Channel Number ll,mm = Video Fader Value : 00H, 00H - 0FH, 7FH (0 - 2047)
  • Page 8: Messages Transmitted In V-Link Master Mode

    This is the message for actual data transmission. Use this when you want to set data for the device. Status Data Byte Status 41H,dev,00H,51H,12H,aaH,bbH,ccH,ddH,…,eeH,sum Byte Explanation Exclusive Status ID Number (Roland) Device ID Model ID Upper Byte (V-LINK Message) Model ID Lower Byte (V-LINK Message) Command ID (DT1) Address Upper Byte Address Address Data : Actual data.
  • Page 9: Messages Received In V-Link Slave Mode

    MIDI Implementation Messages Received in V-LINK Slave Mode Program Change Status 2nd Byte n = Ctrl Rx MIDI Ch. Number : 0H-FH (Ch. 1-16) pp = PST Cross-point Number : 00H -04H (CH1 - Background) * The Dissolve Time is automatically adjusted when the Auto Mix Mode is ON. Note On Status 2nd Byte...
  • Page 10 This is the message for actual data transmission. Use this when you want to set data for the device. Status Data Byte Status 41H,dev,00H,51H,12H,aaH,bbH,ccH,ddH,…,eeH,sum Byte Explanation Exclusive Status ID Number (Roland) Device ID Model ID Upper Byte (V-LINK Message) Model ID Lower Byte (V-LINK Message) Command ID (DT1) Address Upper Byte Address Address Data : Actual data.
  • Page 11: Messages Received In Mvc Mode

    MIDI Implementation Messages Received in MVC Mode Program Change Status 2nd Byte n = MIDI Channel Number (CCM): 0H-FH (Ch. 1-16) pp = Channel Number : 00H -04H (CH1 - Background) Note On Status 2nd Byte 3rd Byte n = MIDI Channel Number (CCM): 0H-FH (Ch. 1-16) kk = Note Number : 00H-7FH (0-127) Note Off Status...
  • Page 12 MIDI Implementation Universal System Exclusive 7EH Dev OCH 01H {. . .} MIDI Visual Control Data Set MIDI Visual Control Data Set is made of data address, actual data to be transmitted and the checksum. upper address middle data lower Byte Explanation System Exclusive Status...
  • Page 13: Appendices

    Exclusive message and checksum calculation Roland exclusive messages (RQ1, DT1) contain a checksum following the data (after F7), which can be used to check whether the message was received correctly. The checksum value is derived from the address and data (or size) of the transmitted exclusive message.
  • Page 14: Rs-232C Command Reference

    RS-232C Command Reference It is possible to remote control the V-40HD from an external device using the RS-232C jack. Specification of the RS-232C Jack fig.RS-232C.eps Pin No. Signal Communication method Synchronous (asynchronous), full-duplex Communication speed 9600 bps Parity none Data length...
  • Page 15: Commands Transmitted From An External Device

    RS-232C Command Reference Commands Transmitted from an External Device stxHRC:a; stxHDL:a; 0(HDMI), 1(RGB/Component), 2(Composite), 3(Shared Input) Time 0(0.0 frame) - 120(12.0 frames) a;Source Select a;HDMI Audio Delay Set stxPGM:a; stxFDE:a; PGM Channel Number 0(CH 1) - 4(Background) 0:OFF 1:ON a;PGM Channel Select a;Output Fade Start stxPST:a;...
  • Page 16: Data Transmitted From The V-800Hd

    0 (syntax error) The command contains error. 5 (out of range error) The command is out of range.VER stxVER: V-40HD, a; a;Version This is transmitted when the unit receives VER command. * The version info is ASCII text strings. Flow Control...