Setting
Needle bar safety bight stop
Check
1. The needle should be set to its maximum zig-zag position and the needle set to its right hand
position in needle plate.
2. When the needle bar is pushed to its most right position, by hand, the needle should just
slightly touch the right hand sides needle plate slot end.
Adjustment
Adjust the bight stop by moving the thread guide that is located under the face plate.
1. Set the stitch width selector to a maximum zig-zag position.
2. Turn handwheel so the needle comes to its most right position, with the point of needle a little
inside the needle plate slot.
4. Loosen the two screws (a) .
5. Push the needle bar to the right until the needle slightly touches the needle plate slot end.
5. push the guide line (b) until it touches the bracket (c).
5. Readjust if necessary.
Singer Inspiration