Installing Or Replacing A Drive: 2077-92F, 2077-A9F - IBM Storwize V5100 MTM 2078-424 Quick Installation Manual

Table of Contents

Advertisement

Align the tab on each side of the 1U fascia with the corresponding slots on the enclosure flange. Pins
on each flange must also align with a hole in each side of the 1U fascia.
Figure 37. Replace fascia components on the expansion enclosure

Installing or replacing a drive: 2077-92F, 2077-A9F

Use the following procedure to install a drive for the first time or to replace a faulty drive in a 2077-92F,
2077-A9F expansion enclosure with a new one received from FRU stock.
Before you begin
Important:
• You can replace a drive assembly without powering off the expansion enclosure. However, to maintain
operating temperature, do not keep the cover off an operational enclosure for more than 15 minutes.
The reduction in airflow through the enclosure might cause the enclosure or its components to shut
down to protect from overheating.
• Ensure that the drive that you are replacing is not a spare or a member of an array. The drive status is
shown in Pools > Internal Storage in the management GUI. If the drive is a member of an array, follow
the fix procedures in the management GUI. The fix procedures minimize the risk of losing data or access
to data; the procedures also manage the system's use of the drive.
44 Storwize V5100 : Quick Installation Guide for MTM 2078-424, 2078-12F, 2078-24F, 2078-92F, and 2078-