OPERATING PARAMETERS

PRESSURES AND FLOW RATES
For optimum performance, supply pressures should be nominally equal under flow conditions.
Recommended Minimum Supply Pressure: 500 kPa
Recommended Minimum Flow Rate at mid-blend with equal supply pressures (see table below)
Nominal Flow Rate at mid-blend for a maximum pressure loss of 250 kPa (see table below)
Maximum Supply Pressure: 1000 kPa
Model
940 08001
940 16001
940 24001
Minimum Flow Rate (L/min)
8
16
24
Nominal Flow Rate (L/min)
80
160
240
Note: the above pressure/flow graph relates to a single valve unit. For multiple valve units, multiply the flow rate
on the vertical axis by the number of valves to give the total system flow at a given pressure loss.
TEMPERATURES
Minimum Cold Water Temperature: 1°C
Maximum Hot Water Temperature: 70°C*
Minimum Hot Water Supply Temperature: Blend water temperature plus 15°C
Maximum Cold Water Supply Temperature: Blend water temperature less 15°C
Thermostatic Control Range: approximately 25°C - 60°C
Optimum Thermostatic Control Range: 35°C - 50°C
*Note! For optimum performance reasons it is recommended that the maximum hot water temperature is limited
to 65°C.
Caution! During thermal disinfection the mixing valve can operate up to 85°C for short periods. Ensure safety
precautions are followed during discharge. Chemical disinfection agents e.g.chlorine/chloramines combined with
higher temperatures will affect the life of the product adversely and could detrimentally affect the thermostatic
performance.