Exposure Start trigger determines exposure start timing, Exposure End trigger determines exposure end timing.
To operate the camera under this mode, the following settings have to be set.
・Exposure Mode: Trigger Controlled
・Selects Trigger Selector: Exposure Start, and Trigger Mode: On
(*) On Trigger Mode except Frame Start should be set Off.
Timing
トリガー入力(正極性)
トリガー入力(負極性)
露光
映像出力
This function can apply either external signal or a software command as the trigger.
The software trigger can be applied through the "execute Trigger Software" command when the trigger is
selected on the Trigger Selector.
STC-MBCM200U3V / STC-MCCM200U3V / STC-MBCM200U3V-NIR
STC-MBCM401U3V / STC-MCCM401U3V / STC-MBCM401U3V-NIR Product Specifications and Use's Guide
Trigger Input
(Positive)
I/O Delay (tIPDLH)
I/O遅延(tIPDLH)
Trigger Input
(Negative)
I/O Delay (tIPDHL)
I/O遅延(tIPDHL)
Exposure
VideoOut
LineDebounceTime
Trigger Delay
TriggerDelay
Exposure Start Duration inside of sensor
センサー内部の露光開始遅延
ExposureTime